YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Evaluation of the Shear Bond Strength of Various Adhesives on the Surface of Enamel Irradiated With Various Doses of Radiotherapy

dc.authorid Tunca, Murat/0000-0002-9157-9390
dc.authorid Fahrzadeh, Nihal/0000-0003-2137-5453
dc.authorscopusid 58670981200
dc.authorscopusid 57210285697
dc.authorwosid Fahrzadeh, Nihal/Jvm-9056-2024
dc.authorwosid Tunca, Murat/Aaz-1662-2020
dc.contributor.author Fahrzadeh, Nihal
dc.contributor.author Tunca, Murat
dc.date.accessioned 2025-05-10T17:23:35Z
dc.date.available 2025-05-10T17:23:35Z
dc.date.issued 2024
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Fahrzadeh, Nihal; Tunca, Murat] Van Yuzuncu Yil Univ, Dept Prosthodont, Fac Dent, Van, Turkiye en_US
dc.description Tunca, Murat/0000-0002-9157-9390; Fahrzadeh, Nihal/0000-0003-2137-5453 en_US
dc.description.abstract Introduction: We aimed to compare the shear bond strength (SBS) forces on the enamel surface with 2 adhesives after treatment with various radiation doses. Methods: A total of 120 premolars were included in the study. The teeth were randomly divided into 5 main groups (n = 24): negative control (without aging), positive control (with aging), 40 Gy, 60 Gy, and 70 Gy radiation. The 40 Gy, 60 Gy, and 70 Gy groups underwent conventional radiotherapy 5 days a week with a dose of 2 Gy each day. After the radiotherapy, all samples except the negative control group were subjected to thermal cycle aging. In all 5 groups, the specimens were divided into 2 subgroups, and half were bonded using 2 adhesives. After bonding, the universal Shimadzu test device was used to analyze the SBS. After the test, the tooth surfaces were examined under a stereomicroscope to determine the adhesive remnant index. Results: When adhesives were compared, Biofix adhesive's bond strength value was statistically higher in the 40 Gy group than in the Transbond XT group (P = 0.001). The SBS value was higher in all irradiated groups than in nonirradiated groups (P = 0.001). When the adhesive remnant index score was analyzed, no significant difference was found among the groups. Conclusions: The SBS increased in irradiated teeth compared with unirradiated teeth, and the SBS values of both adhesives were within the acceptable limits in all radiation groups. (Am J Orthod Dentofacial Orthop 2024;165:285-93) en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1016/j.ajodo.2023.09.008
dc.identifier.endpage 293 en_US
dc.identifier.issn 0889-5406
dc.identifier.issn 1097-6752
dc.identifier.issue 3 en_US
dc.identifier.pmid 37897485
dc.identifier.scopus 2-s2.0-85175243363
dc.identifier.scopusquality Q1
dc.identifier.startpage 285 en_US
dc.identifier.uri https://doi.org/10.1016/j.ajodo.2023.09.008
dc.identifier.uri https://hdl.handle.net/20.500.14720/10925
dc.identifier.volume 165 en_US
dc.identifier.wos WOS:001194002100001
dc.identifier.wosquality Q2
dc.language.iso en en_US
dc.publisher Mosby-elsevier en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.title Evaluation of the Shear Bond Strength of Various Adhesives on the Surface of Enamel Irradiated With Various Doses of Radiotherapy en_US
dc.type Article en_US

Files