YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Disposable Concentric Needle Electromyography Electrodes Artifact Discharge Mimicking Positive Sharp Waves

dc.authorscopusid 6701642517
dc.authorscopusid 57200077842
dc.authorscopusid 6603706748
dc.authorscopusid 55967233000
dc.authorscopusid 57206834494
dc.contributor.author Anlar, Ö.
dc.contributor.author Baslo, M.B.
dc.contributor.author Ertaş, M.
dc.contributor.author Oge, A.E.
dc.contributor.author Yazici, J.
dc.date.accessioned 2025-05-10T17:51:04Z
dc.date.available 2025-05-10T17:51:04Z
dc.date.issued 2003
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp Anlar Ö., Yuzuncu Yil University, Faculty of Medicine, Department of Neurology, 65200 Van, Turkey; Baslo M.B., Istanbul University, Medical School, Istanbul, Turkey; Ertaş M., Istanbul University, Medical School, Istanbul, Turkey; Oge A.E., Istanbul University, Medical School, Istanbul, Turkey; Yazici J., Istanbul University, Medical School, Istanbul, Turkey en_US
dc.description.abstract Objectives: To determine a new artifact discharge produced from the disposable concentric needle (DCN) electromyography (EMG) electrodes. Methods: We have recorded the activity obtained after the first insertion of 41 DCN (37 mm) and 36 DCN (50 mm) in several muscles during the rest. The number of the patients was 77 (26 male, 51 female). Results: We observed an artifact discharge (AD) resembling positive sharp waves (PSWs) in 31 patients of 77 insertions. The AD occurred with 18 of 41 insertions of DCN 37 mm and 13 of DCN 50 mm. The artifact resolved when the needle has been moved in the muscle or in the adipose subcutaneous tissue. Conclusion: This AD should be recognized when using DCN electrodes to avoid confusion with PSWs. Recognizing these artifacts during needle EMG is important to avoid false positive results. en_US
dc.identifier.endpage 39 en_US
dc.identifier.issn 0301-150X
dc.identifier.issue 1 en_US
dc.identifier.pmid 12613139
dc.identifier.scopus 2-s2.0-0037263427
dc.identifier.scopusquality N/A
dc.identifier.startpage 37 en_US
dc.identifier.uri https://hdl.handle.net/20.500.14720/17979
dc.identifier.volume 43 en_US
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.relation.ispartof Electromyography and Clinical Neurophysiology en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Artifact Discharge en_US
dc.subject Disposable Concentric Needle en_US
dc.subject Electromyography en_US
dc.title Disposable Concentric Needle Electromyography Electrodes Artifact Discharge Mimicking Positive Sharp Waves en_US
dc.type Article en_US