YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Voltammetric Behavior of Testosterone on Bismuth Film Electrode: Highly Sensitive Determination in Pharmaceuticals and Human Urine by Square-Wave Adsorptive Stripping Voltammetry

dc.authorid Senturk, Zuhre/0000-0002-0356-9345
dc.authorid Yardim, Yavuz/0000-0002-9587-096X
dc.authorid Levent, Abdulkadir/0000-0001-5792-419X
dc.authorscopusid 6602133530
dc.authorscopusid 57197640224
dc.authorscopusid 56587634000
dc.authorscopusid 55511747958
dc.authorscopusid 7004177719
dc.authorwosid Senturk, Zuhre/Aas-5179-2020
dc.authorwosid Levent, Abdulkadir/V-5418-2017
dc.contributor.author Levent, Abdulkadir
dc.contributor.author Altun, Ahmet
dc.contributor.author Tas, Suleyman
dc.contributor.author Yardim, Yavuz
dc.contributor.author Senturk, Zuhre
dc.date.accessioned 2025-05-10T17:37:44Z
dc.date.available 2025-05-10T17:37:44Z
dc.date.issued 2015
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Levent, Abdulkadir; Altun, Ahmet; Tas, Suleyman] Batman Univ, Hlth Serv Vocat Coll, TR-72100 Batman, Turkey; [Yardim, Yavuz] Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkey; [Senturk, Zuhre] Yuzuncu Yil Univ, Fac Sci, Dept Analyt Chem, TR-65080 Van, Turkey en_US
dc.description Senturk, Zuhre/0000-0002-0356-9345; Yardim, Yavuz/0000-0002-9587-096X; Levent, Abdulkadir/0000-0001-5792-419X en_US
dc.description.abstract In this paper, an electrochemical application of bismuth-film electrode (BiFE) fabricated via ex-situ electrodeposition onto a glassy carbon electrode for testosterone determination was investigated in aqueous and aqueous/surfactant solutions. In cyclic voltammetry, the compound showed one irreversible and adsorption-controlled reduction peak. The BiFE revealed good linear response in the examined concentration range of 1 to 45 nmolL(-1) testosterone in Britton-Robinson buffer, pH 5.0 containing 3 mmolL(-1) cetyltrimethylammonium bromide. The limit of detection was 0.3 nmolL(-1) (0.09 ng mL(-1)). Finally, the BiFE was satisfactorily applied for quantitation of testosterone in both pharmaceutical (oil-based ampoule) and biological (human urine) samples. en_US
dc.description.sponsorship Scientific Research Projects Presidency of Batman University [2011-FED-7] en_US
dc.description.sponsorship This project was financially supported by the Scientific Research Projects Presidency of Batman University (2011-FED-7). en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1002/elan.201400627
dc.identifier.endpage 1228 en_US
dc.identifier.issn 1040-0397
dc.identifier.issn 1521-4109
dc.identifier.issue 5 en_US
dc.identifier.scopus 2-s2.0-84929131202
dc.identifier.scopusquality Q2
dc.identifier.startpage 1219 en_US
dc.identifier.uri https://doi.org/10.1002/elan.201400627
dc.identifier.uri https://hdl.handle.net/20.500.14720/14477
dc.identifier.volume 27 en_US
dc.identifier.wos WOS:000356605100020
dc.identifier.wosquality Q2
dc.language.iso en en_US
dc.publisher Wiley-v C H verlag Gmbh en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Adsorptive Stripping Voltammetry en_US
dc.subject Bismuth-Film Electrode en_US
dc.subject Cetyltrimethylammonium Bromide en_US
dc.subject Pharmaceutical And Biological Samples en_US
dc.subject Testosterone en_US
dc.title Voltammetric Behavior of Testosterone on Bismuth Film Electrode: Highly Sensitive Determination in Pharmaceuticals and Human Urine by Square-Wave Adsorptive Stripping Voltammetry en_US
dc.type Article en_US

Files