Rapid Confirmatory Analysis of Avermectin Residues in Milk by Liquid Chromatography Tandem Mass Spectrometry
No Thumbnail Available
Date
2016
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Food & Drug Adminstration
Abstract
CC BY-NC-ND license (http.//creativecommons.org/licenses/by-nc-nd/4.0/).Our study developed a quick method for confirmatory analysis of avermectins (abamectin Bia, doramectin, ivermectin B-1a, eprinomectin B-1a, and moxidectin) in bovine milk according to the European Commission Decision 2002/657(/)EC requirements. Avermectins were liquid liquid extracted with acetonitrile, followed by an evaporation step, and then analyzed by liquid chromatography/electrospray ionization tandem mass spectrometry in the negative ion mode. An in-house method validation was performed and the data reported on specificity, linearity, recovery, limit of detection, limit of quantitation, decision limit, and detection capability. The advantage of this method is that low levels of avermectins are detectable and quantitatively confirmed at a rapid rate in milk. Copyright (C) 2015, Food and Drug Administration, Taiwan. Published by Elsevier Taiwan LLC. This is an open access article under the CC BY-NC-ND license (http.//creativecommons.org/licenses/by-nc-nd/4.0/).
Description
Kahraman, Tahir/0000-0003-4238-8528; Ozdemir, Nurullah/0000-0003-4310-2077
Keywords
Avermectin, Liquid Chromatography/Tandem, Mass Spectrometry, Milk, Residue
Turkish CoHE Thesis Center URL
WoS Q
Q2
Scopus Q
Q2
Source
Volume
24
Issue
1
Start Page
90
End Page
94