YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Ultrasonic Elastography Evaluation in Optic Neuritis

dc.authorid Cilingir, Vedat/0000-0003-4635-2880
dc.authorid Seven, Erbil/0000-0001-5629-291X
dc.authorid Batur, Abdussamet/0000-0003-2865-9379
dc.authorscopusid 36865943600
dc.authorscopusid 55853727900
dc.authorscopusid 56286078700
dc.authorscopusid 57188826172
dc.authorscopusid 6603398171
dc.authorscopusid 15764359300
dc.authorscopusid 15764359300
dc.authorwosid Cinal, Adnan/Iwm-1994-2023
dc.authorwosid Seven, Erbil/Aaj-4613-2020
dc.authorwosid Yasar, Tekin/Aaf-9914-2019
dc.authorwosid Batur, Abdussamet/Aac-1482-2020
dc.contributor.author Batur, Muhammed
dc.contributor.author Batur, Abdussamet
dc.contributor.author Cilingir, Vedat
dc.contributor.author Seven, Erbil
dc.contributor.author Cinal, Adnan
dc.contributor.author Bora, Aydin
dc.contributor.author Yasar, Tekin
dc.date.accessioned 2025-05-10T17:03:52Z
dc.date.available 2025-05-10T17:03:52Z
dc.date.issued 2018
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Batur, Muhammed; Seven, Erbil; Yasar, Tekin] Yuzuncu Yil Univ, Dept Ophthalmol, Fac Med, Van, Turkey; [Batur, Abdussamet; Bora, Aydin] Yuzuncu Yil Univ, Dept Radiol, Fac Med, Van, Turkey; [Cilingir, Vedat] Yuzuncu Yil Univ, Dept Neurol, Fac Med, Van, Turkey; [Cinal, Adnan] Yuzuncu Yil Gazi Univ, Fac Med, Dept Ophthalmol, Ankara, Turkey en_US
dc.description Cilingir, Vedat/0000-0003-4635-2880; Seven, Erbil/0000-0001-5629-291X; Batur, Abdussamet/0000-0003-2865-9379 en_US
dc.description.abstract Purpose: In the present study, we attempted to determine whether ultrasonic elastography (USE) evaluation can be used in a diagnosis of optic neuritis (ON). Materials and Methods: Thirteen patients who each had one normal eye and one eye with a diagnosis of ON were included in the study. Ultrasonography (US) and USE examinations were performed on the affected and non-affected eyes of all participants. Optic nerve and adjacent fat tissue regions at the same depth were selected, and USE measurements were obtained. The optic nerve diameter was measured in both normal and affected eyes. Results: The mean USE values for the optic nerve were 2.58 +/- 0.50 m/s in ON eyes and 1.91 +/- 0.39 m/s in normal eyes (p = 0.001). The mean USE values for the optic-nerve adjacent tissue were 2.26 +/- 0.45 m/s in ON eyes and 1.77 +/- 0.22 m/s in normal eyes (p = 0.001). The mean optic-nerve diameter was 3.80 +/- 1.09 mm in ON eyes and 3.28 +/- 0.98 mm in normal eyes (p = 0.005). Conclusions: USE may be considered an accessible, safe technique for the detection of significant optic-nerve tissue stiffness in ON and may be used an adjunctive tool for confirming this diagnosis. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1080/08820538.2016.1208765
dc.identifier.endpage 241 en_US
dc.identifier.issn 0882-0538
dc.identifier.issn 1744-5205
dc.identifier.issue 2 en_US
dc.identifier.pmid 27628306
dc.identifier.scopus 2-s2.0-84987926759
dc.identifier.scopusquality Q2
dc.identifier.startpage 237 en_US
dc.identifier.uri https://doi.org/10.1080/08820538.2016.1208765
dc.identifier.uri https://hdl.handle.net/20.500.14720/5832
dc.identifier.volume 33 en_US
dc.identifier.wos WOS:000428838600018
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Taylor & Francis inc en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Optic Nerve Optic Nerve Diameter en_US
dc.subject Optic Nerve Stiffness en_US
dc.subject Ultrasonic Elastography en_US
dc.subject Ultrasonography en_US
dc.title Ultrasonic Elastography Evaluation in Optic Neuritis en_US
dc.type Article en_US

Files