YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Micro-Shear Bond Strength of Adhesive Resins To Enamel at Different Relative Humidity Conditions

dc.authorid Ozcan, Mutlu/0000-0002-9623-6098
dc.authorscopusid 30067541100
dc.authorscopusid 55753932800
dc.authorscopusid 57189625937
dc.authorscopusid 35320261700
dc.authorscopusid 55753800700
dc.authorscopusid 6602789050
dc.authorscopusid 6602789050
dc.authorwosid Özcan, Mutlu/B-2862-2013
dc.contributor.author Bavbek, Andac Barkin
dc.contributor.author Demir, Erhan
dc.contributor.author Goktas, Baris
dc.contributor.author Ozcopur, Betul
dc.contributor.author Behram, Benin
dc.contributor.author Eskitascioglu, Gurcan
dc.contributor.author Ozcan, Mutlu
dc.date.accessioned 2025-05-10T17:44:53Z
dc.date.available 2025-05-10T17:44:53Z
dc.date.issued 2013
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Bavbek, Andac Barkin; Demir, Erhan; Goktas, Baris; Behram, Benin; Eskitascioglu, Gurcan] Yuzuncu Yil Univ, Fac Dent, Dept Prosthodont, TR-65080 Kampus, Van, Turkey; [Ozcopur, Betul] Yuzuncu Yil Univ, Fac Dent, Dept Endodont, TR-65080 Kampus, Van, Turkey; [Ozcan, Mutlu] Univ Zurich, Dent Mat Unit, Ctr Dent & Oral Med, Clin Fixed & Removable Prosthodont & Dent Mat Sci, CH-8032 Zurich, Switzerland en_US
dc.description Ozcan, Mutlu/0000-0002-9623-6098 en_US
dc.description.abstract This study tested whether exhaled humid conditions would affect the adhesion of etch-and-rinse, two-step and one-step self-etch adhesive resins to enamel. Enamel surfaces of human maxillary anterior teeth (N=240, n=20) were exposed to four humid conditions (H1: 63-68%, H2: 73-78%, H3: 93-98%, H4: 36-45% RH) during bonding with Adper Single Bond 2 (SB2), Clearfil SE Bond (CSE) and Adper Easy Bond (AEB). Specimens were stored in distilled water at 37 degrees C for 24 h and tested to failure using micro-shear bond strength (mu SBS) test. Data were analyzed using two-way ANOVA and Tukey's test (p<0.05). The mu SBS to enamel with SB2, CSE and AEB was not significantly affected by humidity parameters. AEB resulted in significantly lower mu SBS in all conditions. The frequency of adhesive failures was the highest at H2, H3 for SB2, H3 for CSE and H1-4 for AEB indicating that humidity conditions may decrease adhesion quality to enamel. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.4012/dmj.2012-200
dc.identifier.endpage 475 en_US
dc.identifier.issn 0287-4547
dc.identifier.issue 3 en_US
dc.identifier.pmid 23719010
dc.identifier.scopus 2-s2.0-84878470847
dc.identifier.scopusquality Q2
dc.identifier.startpage 468 en_US
dc.identifier.uri https://doi.org/10.4012/dmj.2012-200
dc.identifier.uri https://hdl.handle.net/20.500.14720/16195
dc.identifier.volume 32 en_US
dc.identifier.wos WOS:000322358300018
dc.identifier.wosquality Q3
dc.language.iso en en_US
dc.publisher Japanese Soc dental Materials devices en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Adhesion en_US
dc.subject Micro-Shear Bond Strength en_US
dc.subject Relative Humidity en_US
dc.subject Self-Etch Adhesive Resin en_US
dc.subject Total-Etch System en_US
dc.title Micro-Shear Bond Strength of Adhesive Resins To Enamel at Different Relative Humidity Conditions en_US
dc.type Article en_US

Files