Micro-Spoon Technique in Estimation of Sperm Concentration in Rat Epididymis
dc.authorscopusid | 6701806515 | |
dc.authorscopusid | 6506497279 | |
dc.authorscopusid | 6701482226 | |
dc.authorscopusid | 7007034359 | |
dc.authorscopusid | 6508191712 | |
dc.authorscopusid | 7005387014 | |
dc.contributor.author | Odabas, Ö | |
dc.contributor.author | Timurkan, H | |
dc.contributor.author | Atilla, MK | |
dc.contributor.author | Yilmaz, Y | |
dc.contributor.author | Sengül, E | |
dc.contributor.author | Aydin, S | |
dc.date.accessioned | 2025-05-10T17:12:36Z | |
dc.date.available | 2025-05-10T17:12:36Z | |
dc.date.issued | 2000 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | Yuzuncu Univ, Sch Med, Dept Urol, Tip Fak Hastanesi, Van, Turkey | en_US |
dc.description.abstract | Several technical procedures mere described for estimation of epididymal sperm concentration until today. In all of the described techniques, epididymal material was drawn into a micro-pipette before counting procedure. We aimed to proceed this stage without using any pipette because of the difficulty in aspirating very viscous epididymal material into a micro-pipette. For measuring epididymal material we used a 2 mu l reservoir which me named as a micro-spoon. It was filled with the epididymal material and layered in a tube with Ringer's solution of 2 mi containing sodium hyaluronate. Then, it was mixed in order to obtain 1/1000 diluted suspension. Sperm cells in this suspension were counted on a Makler chamber under a light microscope. The procedure was easy and time saving, compared to the other techniques. (C) 2000 Tohoku University Medical Press. | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.doi | 10.1620/tjem.191.1 | |
dc.identifier.endpage | 5 | en_US |
dc.identifier.issn | 0040-8727 | |
dc.identifier.issn | 1349-3329 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.pmid | 10896034 | |
dc.identifier.scopus | 2-s2.0-0034182970 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 1 | en_US |
dc.identifier.uri | https://doi.org/10.1620/tjem.191.1 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/7924 | |
dc.identifier.volume | 191 | en_US |
dc.identifier.wos | WOS:000087963100001 | |
dc.identifier.wosquality | Q3 | |
dc.language.iso | en | en_US |
dc.publisher | Tohoku Univ Medical Press | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Micro-Spoon | en_US |
dc.subject | Cauda Epididymis | en_US |
dc.subject | Sperm Concentration | en_US |
dc.title | Micro-Spoon Technique in Estimation of Sperm Concentration in Rat Epididymis | en_US |
dc.type | Article | en_US |