YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Predictive Value of Magnetic Resonance Imaging Signal and Contrast-Enhancement Characteristics on Post-Embolization Volume Reduction of Uterine Fibroids

dc.authorid Etlik, Omer/0009-0000-9266-3941
dc.authorscopusid 7006379045
dc.authorscopusid 8408485500
dc.authorscopusid 35465864900
dc.authorscopusid 6701777711
dc.authorscopusid 6701497959
dc.authorwosid Arslan, Halil/Aac-5244-2020
dc.contributor.author Harman, M
dc.contributor.author Zeteroglu, S
dc.contributor.author Arslan, H
dc.contributor.author Sengül, M
dc.contributor.author Etlik, Ö
dc.date.accessioned 2025-05-10T17:29:09Z
dc.date.available 2025-05-10T17:29:09Z
dc.date.issued 2006
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp Yuzuncu Yil Univ, Fac Med, Dept Radiol, Van, Turkey; Yuzuncu Yil Univ, Fac Med, Dept Obstet & Gynecol, Van, Turkey en_US
dc.description Etlik, Omer/0009-0000-9266-3941 en_US
dc.description.abstract Purpose: To assess the magnetic resonance imaging (MRI) signal and contrast-enhancement features of uterine fibroids before and after embolization, and to determine whether or not there are pre-embolization MRI characteristics that predict the volume reduction of fibroids. Material and Methods: Uterine fibroid embolization (UFE) was carried out in 28 fibroids of 20 patients, all of whom were symptomatic. The patients were prospectively evaluated with T1-weighted, T2-weighted, and gadolinium-enhanced T1 MRI sequences before and 6 months after embolization. The relationship between the characteristics of MRI signal and contrast-enhancement features of fibroids before the procedure and the change in size of the lesions after treatment was investigated. Results: Before embolization, the mean volume of fibroids was 123 cm(3) (8-560 cm(3)). The decrease rate in fibroid volumes was 44.6% (range 7-70%) 6 months after embolization. Volume reduction was more prominent in fibroids that had a high signal intensity on T2-weighted images and a marked contrast enhancement on T1-weighted images (P < 0.001). However, the volume reduction was insufficient in fibroids with high signal characteristics on pre-contrast T1-weighted images (P < 0.001). Conclusion: MRI is an effective method for revealing size and signal changes of fibroids after embolization. MRI signal characteristics and the contrast-enhancement pattern of fibroids before embolization can predict tumor volume reduction after embolization. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1080/02841850600557117
dc.identifier.endpage 435 en_US
dc.identifier.issn 0284-1851
dc.identifier.issn 1600-0455
dc.identifier.issue 4 en_US
dc.identifier.pmid 16739706
dc.identifier.scopus 2-s2.0-33646415367
dc.identifier.scopusquality Q3
dc.identifier.startpage 427 en_US
dc.identifier.uri https://doi.org/10.1080/02841850600557117
dc.identifier.uri https://hdl.handle.net/20.500.14720/12263
dc.identifier.volume 47 en_US
dc.identifier.wos WOS:000237221800018
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Sage Publications Ltd en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Embolization en_US
dc.subject Magnetic Resonance Imaging en_US
dc.subject Uterine Fibroid en_US
dc.title Predictive Value of Magnetic Resonance Imaging Signal and Contrast-Enhancement Characteristics on Post-Embolization Volume Reduction of Uterine Fibroids en_US
dc.type Article en_US

Files