Hunter's Technique Without Hunter's Rod
dc.authorid | Isik, Daghan/0000-0003-2166-8643 | |
dc.authorid | Aydin, Osman Enver/0000-0002-5823-2774 | |
dc.authorscopusid | 8714127200 | |
dc.authorscopusid | 15765935800 | |
dc.authorscopusid | 55479953900 | |
dc.authorscopusid | 36156619700 | |
dc.authorscopusid | 37100971200 | |
dc.authorwosid | Isik, Daghan/J-7738-2015 | |
dc.authorwosid | Aydin, Osman Enver/P-8920-2014 | |
dc.contributor.author | Atik, Bekir | |
dc.contributor.author | Sarici, Murat | |
dc.contributor.author | Kalender, Ali Murat | |
dc.contributor.author | Isik, Daghan | |
dc.contributor.author | Aydin, Osman Enver | |
dc.date.accessioned | 2025-05-10T17:48:00Z | |
dc.date.available | 2025-05-10T17:48:00Z | |
dc.date.issued | 2012 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | [Atik, Bekir] Medeniyet Univ, Dept Plast & Reconstruct Surg, Istanbul, Turkey; [Sarici, Murat] Bitlis State Hosp, Dept Plast & Reconstruct Surg, Bitlis, Turkey; [Kalender, Ali Murat] Kahramanmaras Sutcu Imam Univ, Dept Orthoped, K Maras, Turkey; [Isik, Daghan] Yuzuncu Yil Univ, Dept Plast & Reconstruct Surg, Van, Turkey; [Aydin, Osman Enver] Ataturk Univ, Dept Plast & Reconstruct Surg, Erzurum, Turkey | en_US |
dc.description | Isik, Daghan/0000-0003-2166-8643; Aydin, Osman Enver/0000-0002-5823-2774 | en_US |
dc.description.abstract | Silicon rods initially advocated by Hunter have been widely used in two-stage flexor tendon reconstruction. Two-stage tendoplasty is an expensive procedure; with the addition of the high cost of rods, it is still more expensive. An experimental study investigated cheaper alternatives to silicon rods, but no clinical studies seem to have been reported so far. This study involved 17 patients undergoing two stage flexor tendon grafting. In all fingers, silicon urinary catheters were used as tendon prosthesis. The Wehbe et al modification of the Boyes and Stark classification was used for preoperative classification and Strickland formulation and Buck-Gramcko criteria for postoperative analysis. This clinical study showed that comparable clinical results and proper pseudosheaths for tendon grafting with similar histological and physical features can be obtained using a silicon urinary catheter which is fifty times less costly than Hunter's rod. | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.endpage | 483 | en_US |
dc.identifier.issn | 0001-6462 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.pmid | 23019780 | |
dc.identifier.scopus | 2-s2.0-84868651860 | |
dc.identifier.scopusquality | Q4 | |
dc.identifier.startpage | 479 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/16940 | |
dc.identifier.volume | 78 | en_US |
dc.identifier.wos | WOS:000308453500009 | |
dc.identifier.wosquality | Q4 | |
dc.language.iso | en | en_US |
dc.publisher | Acta Medica Belgica | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Silicon Urinary Catheter | en_US |
dc.subject | Flexor Tendon | en_US |
dc.subject | Staged Reconstruction | en_US |
dc.title | Hunter's Technique Without Hunter's Rod | en_US |
dc.type | Article | en_US |