YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Two-Year Clinical Evaluation of Three Adhesive Systems in Non-Carious Cervical Lesions

dc.authorid Eliguzeloglu Dalkilic, Evrim/0000-0002-1075-9278
dc.authorscopusid 57117844500
dc.authorscopusid 6506911231
dc.authorwosid Dalkılıç, Evrim/Gpk-1321-2022
dc.contributor.author Dalkilic, Evrim Eliguzeloglu
dc.contributor.author Omurlu, Huma
dc.date.accessioned 2025-05-10T16:46:26Z
dc.date.available 2025-05-10T16:46:26Z
dc.date.issued 2012
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Dalkilic, Evrim Eliguzeloglu] Yuzuncu Yil Univ, Dept Restorat Dent & Endodont, Van, Turkey; [Omurlu, Huma] Gazi Univ, Fac Dent, Dept Restorat Dent, Ankara, Turkey en_US
dc.description Eliguzeloglu Dalkilic, Evrim/0000-0002-1075-9278 en_US
dc.description.abstract Objectives: Adhesive systems are continuously being introduced to Dentistry, unfortunately often without sufficient clinical validation. The aim of this study was to evaluate the clinical performance of cervical restorations done with three different adhesive systems. Material and Methods: 158 non-carious cervical lesions of 23 patients were restored with a nanofilled composite resin (Filtek Supreme, 3M/ESPE) combined with Single Bond (3M/ESPE, group SI), Clearfil SE (Kuraray Medical Inc., group CL) and Xeno III (De Trey Dentsply, group XE). In groups SI-B, CL-B and XE-B, the outer surface of the sclerotic dentin was removed by roughening with a diamond bur before application of the respective adhesive systems. In groups CL-BP and XE-BP, after removal of the outer surface of the sclerotic dentin with the bur, the remaining dentin was etched with 37% phosphoric acid and the self-etch adhesive systems Clearfil SE and Xeno III were applied, respectively. Lesions were evaluated at baseline, and restorations after 3 months, 1 year and 2 years using modified USPHS criteria. Results: After 2 years, no significant difference was found between the retention rates of the groups (p>0.05). Although groups CL and SI showed significantly better marginal adaptation than group XE (p<0.05) at 2 years, no significant difference was found between the marginal adaptation of the groups SI-B, CL-B and XE-B (p>0.05). After 2 years no significant difference was observed among the marginal staining results of all groups (p>0.05). Conclusion: Although all adhesive systems showed similar retention rates, Clearfil SE and Single Bond showed better marginal adaptation than Xeno III after 2 years of follow-up. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1590/S1678-77572012000200012
dc.identifier.endpage 199 en_US
dc.identifier.issn 1678-7757
dc.identifier.issn 1678-7765
dc.identifier.issue 2 en_US
dc.identifier.pmid 22666836
dc.identifier.scopus 2-s2.0-84862749703
dc.identifier.scopusquality Q1
dc.identifier.startpage 192 en_US
dc.identifier.uri https://doi.org/10.1590/S1678-77572012000200012
dc.identifier.uri https://hdl.handle.net/20.500.14720/1151
dc.identifier.volume 20 en_US
dc.identifier.wos WOS:000304830800012
dc.identifier.wosquality Q2
dc.language.iso en en_US
dc.publisher Univ Sao Paulo Fac Odontologia Bauru en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Adhesives en_US
dc.subject Dentin en_US
dc.subject Dental Restoration en_US
dc.subject Composite Resins en_US
dc.title Two-Year Clinical Evaluation of Three Adhesive Systems in Non-Carious Cervical Lesions en_US
dc.type Article en_US

Files