YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Evaluation of Diaphragmatic Movement With Mr Fluoroscopy in Chronic Obstructive Pulmonary Disease

dc.authorscopusid 7006393464
dc.authorscopusid 35465864900
dc.authorscopusid 35516930700
dc.authorscopusid 55901209400
dc.authorscopusid 7003508191
dc.authorwosid Arslan, Halil/Aac-5244-2020
dc.authorwosid Ünal, Özkan/Hkv-5257-2023
dc.contributor.author Ünal, Ö
dc.contributor.author Arslan, H
dc.contributor.author Uzun, K
dc.contributor.author Özbay, B
dc.contributor.author Sakarya, ME
dc.date.accessioned 2025-05-10T17:40:33Z
dc.date.available 2025-05-10T17:40:33Z
dc.date.issued 2000
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp Yuzuncu Yil Univ, Fac Med, Dept Radiol, Van, Turkey; Yuzuncu Yil Univ, Fac Med, Dept Chest Dis, Van, Turkey en_US
dc.description.abstract The aim of this study was to show reduction of the diaphragmatic excursion with MR fluoroscopy in patients with chronic obstructive pulmonary disease (COPD) and to compare the results with pulmonary function test (PFT). The study included 13 men and 10 women (average age 56.2) with COPD, and 9 men and 6 women (average age 55.8) as a control group. MR fluoroscopy images with Spoiled Gradient-echo pulse sequence was obtained during deep inspiration and expiration. After examination, over cine-loop display, the highest and lowest positions of the diaphragm were identified and the distance of excursion was measured. Differences in the diaphragmatic excursion between patient and healthy subjects were compared. We have also compared MR fluoroscopy results with PFT. In each person of both groups, excursion of the diaphragm was demonstrated clearly in cine-loop display. Differences of excursion between deepest and highest point of diaphragm were on average 26 and 20 mm, respectively, in the right and left side in patients and 69 and 56 mm in healthy group. Significant correlation was found between expiratory volume in 1 s and MR fluoroscopy results. MR fluoroscopy study showed that there were significant statistical differences in diaphragmatic excursion between patients with COPD and healthy subjects. Expiratory volume in 1 s is closely associated with the diaphragmatic excursion. MR fluoroscopy would seem to be a useful method for showing diaphragmatic excursion. (C) 2001 Elsevier Science Inc. All rights reserved. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1016/S0899-7071(00)00245-X
dc.identifier.endpage 350 en_US
dc.identifier.issn 0899-7071
dc.identifier.issue 6 en_US
dc.identifier.pmid 11368935
dc.identifier.scopus 2-s2.0-17144456065
dc.identifier.scopusquality Q2
dc.identifier.startpage 347 en_US
dc.identifier.uri https://doi.org/10.1016/S0899-7071(00)00245-X
dc.identifier.uri https://hdl.handle.net/20.500.14720/15225
dc.identifier.volume 24 en_US
dc.identifier.wos WOS:000168939900004
dc.identifier.wosquality Q3
dc.language.iso en en_US
dc.publisher Elsevier Science inc en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Diaphragm en_US
dc.subject Magnetic Resonance en_US
dc.subject Rapid Imaging en_US
dc.subject Fluoroscopy en_US
dc.title Evaluation of Diaphragmatic Movement With Mr Fluoroscopy in Chronic Obstructive Pulmonary Disease en_US
dc.type Article en_US

Files