Evaluation of Successful and Failed Filtering Blebs After Trabeculectomy Using Anterior Segment Optical Coherence Tomography
dc.authorscopusid | 57195679419 | |
dc.authorscopusid | 57188826172 | |
dc.authorscopusid | 36865943600 | |
dc.authorscopusid | 57069698700 | |
dc.authorscopusid | 6701592325 | |
dc.authorwosid | Seven, Erbil/Aaj-4613-2020 | |
dc.authorwosid | Ozer, Muhammet/Aaj-3679-2020 | |
dc.contributor.author | Tekin, Serek | |
dc.contributor.author | Seven, Erbil | |
dc.contributor.author | Batur, Muhammed | |
dc.contributor.author | Ozer, Muhammet Derda | |
dc.contributor.author | Yasar, Tekin | |
dc.date.accessioned | 2025-05-10T17:08:01Z | |
dc.date.available | 2025-05-10T17:08:01Z | |
dc.date.issued | 2021 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | [Tekin, Serek; Seven, Erbil; Batur, Muhammed; Ozer, Muhammet Derda] Yuzuncu Yil Univ, Fac Med, Dept Ophthalmol, TR-65080 Tusba, Van, Turkey; [Yasar, Tekin] Beyoglu Eye Res & Training Hosp, Dept Ophthalmol, Istanbul, Turkey | en_US |
dc.description.abstract | Purpose: To evaluate filtering bleb characteristics using anterior segment optical coherence tomography (AS-OCT) and analyze correlations between these parameters and intraocular pressure (IOP). Methods: The study included 54 eyes of 43 patients who underwent trabeculectomy with mitomycin-C. The patients were divided into two groups based on mean postoperative IOP. The criterion for surgical success was mean unmedicated postoperative IOP <= 18 mmHg. Patients with IOP values >18 mmHg were prescribed anti-glaucoma drops and classified as a surgical failure. All patients underwent AS-OCT, and maximum bleb height, maximum bleb wall thickness, and maximum fluid-filled cavity height were measured. AS-OCT bleb parameters were compared between the successful and failed groups. Results: Of the 54 eyes, 37 (68.5%) were in the successful group, and 17 (31.5%) were in the failed group. Mean preoperative IOP values in the successful and failed groups were 26.9 +/- 6.5 mmHg and 22.9 +/- 4.9 mmHg, preoperatively, versus postoperative values of 13.3 +/- 2.1 mmHg and 22.8 +/- 2.8 mmHg, respectively. Mean postoperative follow-up time was 17.4 +/- 9.5 months in the successful group and 19.1 +/- 10.1 months in the failed group (P = 0.22). In the successful and failed groups, mean bleb height was 1473.7 +/- 150.6 mu m and 1165.4 +/- 217 mu m (P < 0.001), bleb wall thickness was 670.5 +/- 119.9 mu m and 538.8 +/- 144.3 mu m (P = 0.001), and fluid-filled cavity height was 736.5 +/- 196.8 mu m versus 532.5 +/- 226.2 mu m (P = 0.001), respectively. Conclusions: The results of this study showed that higher AS-OCT values for bleb height, wall thickness, and fluid-filled cavity height were associated with greater functional success. These parameters may be helpful in determining bleb functionality. | en_US |
dc.description.woscitationindex | Emerging Sources Citation Index | |
dc.identifier.doi | 10.4103/JOCO.JOCO_112_20 | |
dc.identifier.endpage | 5 | en_US |
dc.identifier.issn | 2452-2325 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.pmid | 34084949 | |
dc.identifier.scopus | 2-s2.0-85103616329 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 1 | en_US |
dc.identifier.uri | https://doi.org/10.4103/JOCO.JOCO_112_20 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/6948 | |
dc.identifier.volume | 33 | en_US |
dc.identifier.wos | WOS:000635862900001 | |
dc.identifier.wosquality | N/A | |
dc.language.iso | en | en_US |
dc.publisher | Wolters Kluwer Medknow Publications | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Anterior Segment Optical Coherence Tomography | en_US |
dc.subject | Filtrating Bleb | en_US |
dc.subject | Trabeculectomy | en_US |
dc.title | Evaluation of Successful and Failed Filtering Blebs After Trabeculectomy Using Anterior Segment Optical Coherence Tomography | en_US |