Evaluation of Successful and Failed Filtering Blebs After Trabeculectomy Using Anterior Segment Optical Coherence Tomography

dc.authorscopusid 57195679419
dc.authorscopusid 57188826172
dc.authorscopusid 36865943600
dc.authorscopusid 57069698700
dc.authorscopusid 6701592325
dc.authorwosid Seven, Erbil/Aaj-4613-2020
dc.authorwosid Ozer, Muhammet/Aaj-3679-2020
dc.contributor.author Tekin, Serek
dc.contributor.author Seven, Erbil
dc.contributor.author Batur, Muhammed
dc.contributor.author Ozer, Muhammet Derda
dc.contributor.author Yasar, Tekin
dc.date.accessioned 2025-05-10T17:08:01Z
dc.date.available 2025-05-10T17:08:01Z
dc.date.issued 2021
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Tekin, Serek; Seven, Erbil; Batur, Muhammed; Ozer, Muhammet Derda] Yuzuncu Yil Univ, Fac Med, Dept Ophthalmol, TR-65080 Tusba, Van, Turkey; [Yasar, Tekin] Beyoglu Eye Res & Training Hosp, Dept Ophthalmol, Istanbul, Turkey en_US
dc.description.abstract Purpose: To evaluate filtering bleb characteristics using anterior segment optical coherence tomography (AS-OCT) and analyze correlations between these parameters and intraocular pressure (IOP). Methods: The study included 54 eyes of 43 patients who underwent trabeculectomy with mitomycin-C. The patients were divided into two groups based on mean postoperative IOP. The criterion for surgical success was mean unmedicated postoperative IOP <= 18 mmHg. Patients with IOP values >18 mmHg were prescribed anti-glaucoma drops and classified as a surgical failure. All patients underwent AS-OCT, and maximum bleb height, maximum bleb wall thickness, and maximum fluid-filled cavity height were measured. AS-OCT bleb parameters were compared between the successful and failed groups. Results: Of the 54 eyes, 37 (68.5%) were in the successful group, and 17 (31.5%) were in the failed group. Mean preoperative IOP values in the successful and failed groups were 26.9 +/- 6.5 mmHg and 22.9 +/- 4.9 mmHg, preoperatively, versus postoperative values of 13.3 +/- 2.1 mmHg and 22.8 +/- 2.8 mmHg, respectively. Mean postoperative follow-up time was 17.4 +/- 9.5 months in the successful group and 19.1 +/- 10.1 months in the failed group (P = 0.22). In the successful and failed groups, mean bleb height was 1473.7 +/- 150.6 mu m and 1165.4 +/- 217 mu m (P < 0.001), bleb wall thickness was 670.5 +/- 119.9 mu m and 538.8 +/- 144.3 mu m (P = 0.001), and fluid-filled cavity height was 736.5 +/- 196.8 mu m versus 532.5 +/- 226.2 mu m (P = 0.001), respectively. Conclusions: The results of this study showed that higher AS-OCT values for bleb height, wall thickness, and fluid-filled cavity height were associated with greater functional success. These parameters may be helpful in determining bleb functionality. en_US
dc.description.woscitationindex Emerging Sources Citation Index
dc.identifier.doi 10.4103/JOCO.JOCO_112_20
dc.identifier.endpage 5 en_US
dc.identifier.issn 2452-2325
dc.identifier.issue 1 en_US
dc.identifier.pmid 34084949
dc.identifier.scopus 2-s2.0-85103616329
dc.identifier.scopusquality Q2
dc.identifier.startpage 1 en_US
dc.identifier.uri https://doi.org/10.4103/JOCO.JOCO_112_20
dc.identifier.uri https://hdl.handle.net/20.500.14720/6948
dc.identifier.volume 33 en_US
dc.identifier.wos WOS:000635862900001
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Wolters Kluwer Medknow Publications en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Anterior Segment Optical Coherence Tomography en_US
dc.subject Filtrating Bleb en_US
dc.subject Trabeculectomy en_US
dc.title Evaluation of Successful and Failed Filtering Blebs After Trabeculectomy Using Anterior Segment Optical Coherence Tomography en_US
dc.type Article en_US

Files