YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Monomer Release From Bulk-Fill Composite Resins in Different Curing Protocols

dc.authorid Alp, Hamit Hakan/0000-0002-9202-4944
dc.authorscopusid 55625875700
dc.authorscopusid 24328770500
dc.authorscopusid 7102067681
dc.authorwosid Hakan, Hamit/U-2671-2018
dc.authorwosid Özcan, Mutlu/B-2862-2013
dc.contributor.author Gul, Pinar
dc.contributor.author Alp, Hamit H.
dc.contributor.author Ozcan, Mutlu
dc.date.accessioned 2025-05-10T17:09:14Z
dc.date.available 2025-05-10T17:09:14Z
dc.date.issued 2020
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Gul, Pinar] Ataturk Univ, Fac Dent, Dept Restorat Dent, TR-25240 Erzurum, Turkey; [Alp, Hamit H.] Yuzuncu Yil Univ, Fac Med, Dept Biochem, Van, Turkey; [Ozcan, Mutlu] Univ Zurich, Ctr Dent & Oral Med, Dent Mat Unit, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Zurich, Switzerland en_US
dc.description Alp, Hamit Hakan/0000-0002-9202-4944 en_US
dc.description.abstract The purpose of this study was to determine the depth of cure and the type and amount of monomers released from bulk-fill composites in different curing protocols. Five different composite resins Filtek Bulk-Fill Posterior, Filtek Bulk-Fill Flowable, SureFil SDR, X-tra Fil, and X-tra base. were used. A light-emitting diode (LED) device was used in 3 different modes (standard, high power, and extra power mode), and a halogen light device was also used as a control. Surface hardness was measured and the depth of cure was calculated. Monomer analysis was performed using high performance liquid chromatography (HPLC). The data were analyzed using Tamhane's T2 post-hoc test (alpha = 0.05). The cure depth for all materials except for Filtek Bulk-Fill Posterior (extra power mode) and Filtek Bulk-Fill Flowable (high power and extra power modes) was over 80%. Under the conditions of this study, the amount of monomer released from composite resins changed according to the type of composite resin and the light mode used. en_US
dc.description.sponsorship Ataturk University [2014/165] en_US
dc.description.sponsorship This work was supported by the Research Fund of Ataturk University (Project number: 2014/165) and partially 3M Turkey distributor. In addition, this study was partially presented in TDA 22nd International Dental Congress, 19-21 May 2016, Izmir, Turkey. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.2334/josnusd.19-0221
dc.identifier.endpage 292 en_US
dc.identifier.issn 1343-4934
dc.identifier.issn 1880-4926
dc.identifier.issue 3 en_US
dc.identifier.pmid 32475863
dc.identifier.scopus 2-s2.0-85086946865
dc.identifier.scopusquality Q2
dc.identifier.startpage 288 en_US
dc.identifier.uri https://doi.org/10.2334/josnusd.19-0221
dc.identifier.uri https://hdl.handle.net/20.500.14720/7089
dc.identifier.volume 62 en_US
dc.identifier.wos WOS:000543496600010
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Nihon Univ, School dentistry en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Bulk-Fill Composite Resins en_US
dc.subject Cure Depth en_US
dc.subject Curing Modes en_US
dc.subject Light Curing Units en_US
dc.subject Monomer Release en_US
dc.title Monomer Release From Bulk-Fill Composite Resins in Different Curing Protocols en_US
dc.type Article en_US

Files