YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Comparison of Cerebral Oximeter and Pulse Oximeter Values in the First 72 Hours in Premature, Asphyctic and Healthy Newborns

dc.authorid Sal, Ertan/0000-0003-2761-2675
dc.authorscopusid 26531350600
dc.authorscopusid 36180210800
dc.authorscopusid 26531767700
dc.authorscopusid 26025132600
dc.authorscopusid 14029932700
dc.authorscopusid 56186063400
dc.authorscopusid 56186063400
dc.authorwosid Kostu, Murat/Mbh-5731-2025
dc.authorwosid Sal, Ertan/Aak-1511-2021
dc.authorwosid Okur, Mesut/Aas-6957-2020
dc.contributor.author Kaya, A.
dc.contributor.author Okur, M.
dc.contributor.author Sal, E.
dc.contributor.author Peker, E.
dc.contributor.author Kostu, M.
dc.contributor.author Tuncer, O.
dc.contributor.author Kirimi, E.
dc.date.accessioned 2025-05-10T17:43:03Z
dc.date.available 2025-05-10T17:43:03Z
dc.date.issued 2014
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Kaya, A.; Okur, M.; Sal, E.] Yuzuncu Yil Univ, Fac Med, Dept Pediat, Van, Turkey; [Peker, E.; Kostu, M.; Tuncer, O.; Kirimi, E.] Yuzuncu Yil Univ, Fac Med, Dept Neonatol, Van, Turkey en_US
dc.description Sal, Ertan/0000-0003-2761-2675 en_US
dc.description.abstract Aim: The monitoring of oxygenation is essential for providing patient safety and optimal results. We aimed to determine brain oxygen saturation values in healthy, asphyctic and premature newborns and to compare cerebral oximeter and pulse oximeter values in the first 72 hours of life in neonatal intensive care units. Methods: This study was conducted at the neonatal intensive care unit (NICU) of Van Yuzuncu Yil University Research and Administration Hospital. Seventy-five neonatal infants were included in the study (28 asphyxia, 24 premature and 23 mature healthy infants for control group). All infants were studied within the first 72 hours of life. We used a Somanetics 5100C cerebral oximeter (INVOS cerebral/somatic oximeter, Troy, MI, USA). The oxygen saturation information was collected by a Nellcor N-560 pulse oximeter (Nellcor-Puriton Bennet Inc, Pleasanton, CA, USA). Results: In the asphyxia group, the cerebral oximeter average was 76.85 +/- 14.1, the pulse oximeter average was 91.86 +/- 5.9 and the heart rate average was 139.91 +/- 22.3. Among the premature group, the cerebral oximeter average was 79.08 +/- 9.04, the pulse oximeter average was 92.01 +/- 5.3 and the heart rate average was 135.35 +/- 17.03. In the control group, the cerebral oximeter average was 77.56 +/- 7.6, the pulse oximeter average was 92.82 +/- 3.8 and the heart rate average was 127.04 +/- 19.7. Conclusion: Cerebral oximeter is a promising modality in bedside monitoring in neonatal intensive care units. It is complementary to pulse oximeter. It may be used routinely in neonatal intensive care units. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.7727/wimj.2014.033
dc.identifier.endpage 702 en_US
dc.identifier.issn 0043-3144
dc.identifier.issn 2309-5830
dc.identifier.issue 7 en_US
dc.identifier.pmid 25867556
dc.identifier.scopus 2-s2.0-85034034484
dc.identifier.scopusquality Q4
dc.identifier.startpage 698 en_US
dc.identifier.uri https://doi.org/10.7727/wimj.2014.033
dc.identifier.uri https://hdl.handle.net/20.500.14720/15736
dc.identifier.volume 63 en_US
dc.identifier.wos WOS:000365568800004
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Univ West indies Faculty Medical Sciences en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Monitoring en_US
dc.subject Newborn en_US
dc.subject Neonatal Intensive Care Unit en_US
dc.title Comparison of Cerebral Oximeter and Pulse Oximeter Values in the First 72 Hours in Premature, Asphyctic and Healthy Newborns en_US
dc.type Article en_US