YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

A Novel Glucose Oxidase Biosensor Based on Poly([2,2′; 5′,2"]-Terthiophene Modified Electrode

dc.authorid Kivrak, Arif/0000-0003-4770-2686
dc.authorscopusid 55926493500
dc.authorscopusid 55925236900
dc.authorscopusid 8694518300
dc.authorwosid Kivrak, Arif/Aaq-8432-2021
dc.authorwosid Türkoğlu, Vedat/A-1681-2016
dc.authorwosid Kivrak, Arif/W-2196-2017
dc.contributor.author Guler, Muhammet
dc.contributor.author Turkoglu, Vedat
dc.contributor.author Kivrak, Arif
dc.date.accessioned 2025-05-10T17:11:20Z
dc.date.available 2025-05-10T17:11:20Z
dc.date.issued 2015
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Guler, Muhammet; Turkoglu, Vedat; Kivrak, Arif] Yuzuncu Yil Univ, Fac Sci, Dept Chem, TR-65080 Van, Turkey en_US
dc.description Kivrak, Arif/0000-0003-4770-2686 en_US
dc.description.abstract In the study, the electrochemical behavior of glucose oxidase (GOx) immobilized on poly([2,2';5',2 '']-terthiophene-3'-carbaldehyde) (poly(TTP)) modified glassy carbon electrode (GCE) was investigated. The biosensor (poly(TTP)/GOx/GCE) showed a pair of redox peaks in 0.1 M phosphate buffer (pH 7.4) solution in the absence of oxygen the co-substrate of GOx. In here, Poly(TTP)/GOx/GCE biosensor acts as the co-substrate instead of oxygen. Upon the addition of glucose, the reduction and oxidation peak currents increased until the active site of GOx was fully saturated with glucose. The apparent m was estimated 26.13 mM from Lineweaver-Burk graph. The biosensor displayed a good stability and bioactivity. The biosensor showed a high sensitivity (56.1 nA/mM), a linear range (from 0.5 to 20.15 mM), and a good reproducibility with 3.6% of relative standard deviation. In addition, the interference currents of glycin, ascorbic acid, histidine, uric acid, dopamine, arginine, and fructose on GOx biosensor were investigated. All that substances exhibited an interference current under 10%. It was not shown a marked difference between GOx biosensor and spectrophotometric measurement of glucose in serum examples. UV-visible spectroscopy and scanning electron microscopy (SEM) experiments of the biosensor were also performed. (C) 2015 Elsevier B.V. All rights reserved. en_US
dc.description.sponsorship Presidency of Scientific Research Projects of Yuzuncu Yil University [2013-FBE-D003] en_US
dc.description.sponsorship This work received financial support from Presidency of Scientific Research Projects (2013-FBE-D003) of Yuzuncu Yil University. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1016/j.ijbiomac.2015.04.042
dc.identifier.endpage 268 en_US
dc.identifier.issn 0141-8130
dc.identifier.issn 1879-0003
dc.identifier.pmid 25934105
dc.identifier.scopus 2-s2.0-84929406167
dc.identifier.scopusquality Q1
dc.identifier.startpage 262 en_US
dc.identifier.uri https://doi.org/10.1016/j.ijbiomac.2015.04.042
dc.identifier.uri https://hdl.handle.net/20.500.14720/7710
dc.identifier.volume 79 en_US
dc.identifier.wos WOS:000359166300035
dc.identifier.wosquality Q1
dc.language.iso en en_US
dc.publisher Elsevier Science Bv en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Biosensor en_US
dc.subject Glucose Oxidase en_US
dc.subject Conducting Polymer en_US
dc.title A Novel Glucose Oxidase Biosensor Based on Poly([2,2′; 5′,2"]-Terthiophene Modified Electrode en_US
dc.type Article en_US

Files