YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Pdruo2/Pvp Nanomaterial as a Highly Selective, Stable, and Applicable Potentiometric Sensor for the Detection of Cr3+

dc.authorscopusid 59223297700
dc.authorscopusid 57190129059
dc.authorscopusid 14066714100
dc.authorscopusid 57203179536
dc.authorscopusid 7003266357
dc.authorscopusid 57205595089
dc.authorwosid Yıldız, Ilyas/Iys-8618-2023
dc.contributor.author Cevik, Kenan
dc.contributor.author Yildiz, Ilyas
dc.contributor.author Yildiz, Adnan
dc.contributor.author Nas, Mehmet Salih
dc.contributor.author Alma, Mehmet Hakki
dc.contributor.author Calimli, Mehmet Harbi
dc.date.accessioned 2025-05-10T17:23:16Z
dc.date.available 2025-05-10T17:23:16Z
dc.date.issued 2024
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Cevik, Kenan; Yildiz, Adnan] Yuzuncu Yil Univ, Fac Educ, Dept Secondary Sci & Math Educ, Dept Chem Educ, Van, Turkiye; [Yildiz, Ilyas] Tokat Gaziosmanpasa Univ, Dept Mol Biol & Genet, TR-60000 Tokat, Turkiye; [Nas, Mehmet Salih; Alma, Mehmet Hakki; Calimli, Mehmet Harbi] Igdir Univ, Res Lab Applicat & Res Ctr ALUM, TR-76000 Igdir, Turkiye; [Nas, Mehmet Salih] Igdir Univ, Fac Appl Sci, Dept Organ Agr Management, TR-76000 Igdir, Turkiye; [Calimli, Mehmet Harbi] Igdir Univ, Tuzluca Vocat Sch, Dept Med Serv & Tech, TR-76000 Igdir, Turkiye en_US
dc.description.abstract PdRuO2/PVP nanomaterial was synthesized using a straightforward method and characterized using advanced analytical methods such as TEM, XRD, XPS, elemental mapping and SEM. The synthesized PdRuO2/PVP nanomaterial was used as an ionophore in potentiometric sensor electrodes and successfully adapted to Cr3+ ion detection in a large number of aqueous samples. Several experimental parameters of the PdRuO2/PVP sensor such as potentiometric behavior, selectivity, repeatability, response time, pH, titration, and recovery in real samples were investigated. Potentiometric behavioral characteristics were performed in the concentration range 1 x 10(-6)-1.0 x 10(-1) M. The repeated experiments performed six times showed that there was no deviation in the measurements. The limit of detection of the PdRuO2/PVP potentiometric sensor was very low with a value of 8.6 x 10(-8) M. The potentiometric measurements showed that the synthesized PdRuO2/PVP ionophore was highly effective in detecting Cr3+ in a wide pH range of 2.0-8.0 and was found to have a shelf life of over 1 year. As a result, the synthesized PdRuO2/PVP electrode material was found to be highly selective, stable, and applicable for Cr3+ detection. en_US
dc.description.sponsorship This study was partially supported by Yuzuncu Yil University Scientific Research Projects Support Unit, project numbered FYL 2023 10672. en_US
dc.description.sponsorship No Statement Available en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1007/s00604-024-06543-6
dc.identifier.issn 0026-3672
dc.identifier.issn 1436-5073
dc.identifier.issue 8 en_US
dc.identifier.pmid 39023534
dc.identifier.scopus 2-s2.0-85198846197
dc.identifier.scopusquality Q1
dc.identifier.uri https://doi.org/10.1007/s00604-024-06543-6
dc.identifier.uri https://hdl.handle.net/20.500.14720/10820
dc.identifier.volume 191 en_US
dc.identifier.wos WOS:001272750800001
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Springer Wien en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Potentiometry en_US
dc.subject Sensor en_US
dc.subject Ionophore en_US
dc.subject Chromium(Iii) en_US
dc.subject Nanomaterial en_US
dc.title Pdruo2/Pvp Nanomaterial as a Highly Selective, Stable, and Applicable Potentiometric Sensor for the Detection of Cr3+ en_US
dc.type Article en_US

Files