Pdruo2/Pvp Nanomaterial as a Highly Selective, Stable, and Applicable Potentiometric Sensor for the Detection of Cr3+
dc.authorscopusid | 59223297700 | |
dc.authorscopusid | 57190129059 | |
dc.authorscopusid | 14066714100 | |
dc.authorscopusid | 57203179536 | |
dc.authorscopusid | 7003266357 | |
dc.authorscopusid | 57205595089 | |
dc.authorwosid | Yıldız, Ilyas/Iys-8618-2023 | |
dc.contributor.author | Cevik, Kenan | |
dc.contributor.author | Yildiz, Ilyas | |
dc.contributor.author | Yildiz, Adnan | |
dc.contributor.author | Nas, Mehmet Salih | |
dc.contributor.author | Alma, Mehmet Hakki | |
dc.contributor.author | Calimli, Mehmet Harbi | |
dc.date.accessioned | 2025-05-10T17:23:16Z | |
dc.date.available | 2025-05-10T17:23:16Z | |
dc.date.issued | 2024 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | [Cevik, Kenan; Yildiz, Adnan] Yuzuncu Yil Univ, Fac Educ, Dept Secondary Sci & Math Educ, Dept Chem Educ, Van, Turkiye; [Yildiz, Ilyas] Tokat Gaziosmanpasa Univ, Dept Mol Biol & Genet, TR-60000 Tokat, Turkiye; [Nas, Mehmet Salih; Alma, Mehmet Hakki; Calimli, Mehmet Harbi] Igdir Univ, Res Lab Applicat & Res Ctr ALUM, TR-76000 Igdir, Turkiye; [Nas, Mehmet Salih] Igdir Univ, Fac Appl Sci, Dept Organ Agr Management, TR-76000 Igdir, Turkiye; [Calimli, Mehmet Harbi] Igdir Univ, Tuzluca Vocat Sch, Dept Med Serv & Tech, TR-76000 Igdir, Turkiye | en_US |
dc.description.abstract | PdRuO2/PVP nanomaterial was synthesized using a straightforward method and characterized using advanced analytical methods such as TEM, XRD, XPS, elemental mapping and SEM. The synthesized PdRuO2/PVP nanomaterial was used as an ionophore in potentiometric sensor electrodes and successfully adapted to Cr3+ ion detection in a large number of aqueous samples. Several experimental parameters of the PdRuO2/PVP sensor such as potentiometric behavior, selectivity, repeatability, response time, pH, titration, and recovery in real samples were investigated. Potentiometric behavioral characteristics were performed in the concentration range 1 x 10(-6)-1.0 x 10(-1) M. The repeated experiments performed six times showed that there was no deviation in the measurements. The limit of detection of the PdRuO2/PVP potentiometric sensor was very low with a value of 8.6 x 10(-8) M. The potentiometric measurements showed that the synthesized PdRuO2/PVP ionophore was highly effective in detecting Cr3+ in a wide pH range of 2.0-8.0 and was found to have a shelf life of over 1 year. As a result, the synthesized PdRuO2/PVP electrode material was found to be highly selective, stable, and applicable for Cr3+ detection. | en_US |
dc.description.sponsorship | This study was partially supported by Yuzuncu Yil University Scientific Research Projects Support Unit, project numbered FYL 2023 10672. | en_US |
dc.description.sponsorship | No Statement Available | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.doi | 10.1007/s00604-024-06543-6 | |
dc.identifier.issn | 0026-3672 | |
dc.identifier.issn | 1436-5073 | |
dc.identifier.issue | 8 | en_US |
dc.identifier.pmid | 39023534 | |
dc.identifier.scopus | 2-s2.0-85198846197 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.uri | https://doi.org/10.1007/s00604-024-06543-6 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/10820 | |
dc.identifier.volume | 191 | en_US |
dc.identifier.wos | WOS:001272750800001 | |
dc.identifier.wosquality | N/A | |
dc.language.iso | en | en_US |
dc.publisher | Springer Wien | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Potentiometry | en_US |
dc.subject | Sensor | en_US |
dc.subject | Ionophore | en_US |
dc.subject | Chromium(Iii) | en_US |
dc.subject | Nanomaterial | en_US |
dc.title | Pdruo2/Pvp Nanomaterial as a Highly Selective, Stable, and Applicable Potentiometric Sensor for the Detection of Cr3+ | en_US |
dc.type | Article | en_US |