YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Effect of Orthodontic Brackets on the Accuracy of Apex Locators: a Pilot Study

dc.authorid Genc Sen, Ozgur/0000-0002-3864-9310
dc.authorid , Ozgur Ilke/0000-0001-8779-770X
dc.authorscopusid 56790115100
dc.authorscopusid 10045008700
dc.authorscopusid 57191876117
dc.authorscopusid 23993307300
dc.authorwosid Ulusoy, Cagri/E-7610-2015
dc.authorwosid Ulusoy, Özgür/Afj-8046-2022
dc.contributor.author Sen, Ozgur Genc
dc.contributor.author Ulusoy, Ozgur Ilke
dc.contributor.author Paltun, Yelda Nayir
dc.contributor.author Ulusoy, Cagri
dc.date.accessioned 2025-05-10T17:09:58Z
dc.date.available 2025-05-10T17:09:58Z
dc.date.issued 2021
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Sen, Ozgur Genc] Yuzuncu Yil Univ, Fac Dent, Dept Endodont, Van, Turkey; [Ulusoy, Ozgur Ilke] Gazi Univ, Fac Dent, Dept Endodont, Ankara, Turkey; [Paltun, Yelda Nayir] Minist Hlth, Ankara, Turkey; [Ulusoy, Cagri] Gazi Univ, Dept Orthodont, Fac Dent, Ankara, Turkey en_US
dc.description Genc Sen, Ozgur/0000-0002-3864-9310; , Ozgur Ilke/0000-0001-8779-770X en_US
dc.description.abstract The purpose of this study was to evaluate the effect of metal orthodontic brackets on the accuracy of electronic apex locator (EAL). The actual canal lengths (ACL) of 40 mandibular incisor teeth were determined. Then, the teeth were randomly divided into two groups (n=20). Orthodontic metal brackets were applied in the first group, and no brackets, in the second group. The working length of each tooth was measured with an EAL under 3 test conditions according to the distance between the lip clip and sample tooth. Data were analyzed using one-way repeated measures analysis of variance and Tukey's post hoc tests (p=0.05). In the bracketed samples, when the lip clip was located at 1 cm and 2 cm from the samples. The mean differences between the EAL measurements and ACLs were statistically higher than those when the samples were located 3 cm from the lip clip (p<0.05). There were also statistically significant differences between EAL measurements and ACLs in the bracketed samples located 1 and 2 cm from the lip clip (p<0.05). In the nonbracketed group, the differences between EAL measurements and ACLs were not statistically significant in the samples located 1, 2, and 3 cm from the lip clip (p>0.05). Use of orthodontic metal brackets can negatively influence the accuracy of the electronic apex locator when the distance between the lip clip and bracket was short. A minimum of 3 cm distance should be kept between the lip clip and tooth in order to make consistent electronic measurements. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1155/2021/6615560
dc.identifier.issn 2314-6133
dc.identifier.issn 2314-6141
dc.identifier.pmid 33987442
dc.identifier.scopus 2-s2.0-85105734595
dc.identifier.scopusquality Q1
dc.identifier.uri https://doi.org/10.1155/2021/6615560
dc.identifier.uri https://hdl.handle.net/20.500.14720/7293
dc.identifier.volume 2021 en_US
dc.identifier.wos WOS:000655126400003
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Hindawi Ltd en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title Effect of Orthodontic Brackets on the Accuracy of Apex Locators: a Pilot Study en_US
dc.type Article en_US

Files