YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Comparison of Blood Βhba Measurement Devices for Diagnosis of Subclinical Pregnancy Toxaemia in Sheep: a Field Study

dc.authorscopusid 58606591500
dc.authorscopusid 57211366971
dc.authorscopusid 59151664900
dc.authorwosid Koca, Davut/Aai-6709-2021
dc.authorwosid Turgut, Ali Osman/Lif-0731-2024
dc.contributor.author Turgut, Ali Osman
dc.contributor.author Koca, Davut
dc.contributor.author Unver, Ali
dc.date.accessioned 2025-05-10T17:22:59Z
dc.date.available 2025-05-10T17:22:59Z
dc.date.issued 2024
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Turgut, Ali Osman] Siirt Univ, Fac Vet Med, Dept Anim Sci, Siirt, Turkiye; [Koca, Davut] Van Yuzuncu Yil Univ, Fac Vet Med, Dept Obstet & Gynecol, Van, Turkiye; [Unver, Ali] Siirt Univ, Fac Vet Med, Dept Obstet & Gynecol, Siirt, Turkiye en_US
dc.description.abstract Pregnancy toxaemia is a serious disease that occurs during the last trimester of pregnancy in sheep. Yet, in most cases, the disease may have a subclinical course. This study was aimed at comparing blood beta HBA measurement devices for diagnosis of subclinical pregnancy toxaemia in late pregnant sheep. In the study, a total of 50 blood samples were collected from Romanov (n = 30) and cross-bred Hamdani (n = 20) sheep. Blood beta HBA levels were measured using TaiDoc TD-4235 and CentriVet beta HBA hand-held meter. Randox beta HBA (Ranbut) assay was used as a reference laboratory method to compare hand-held meters. beta HBA value of 0.8 mmol/L was set as the cut-off value for diagnosis of subclinical pregnancy toxaemia. Statistical analyses were carried out using Minitab 21 and Jamovi software. In the study, the correlation of Randox-TaiDoc TD-4235 and Randox-CentriVet was .822 (p < .001) and .728 (p < .001), respectively. Based on the Ranbut assay, nine ewes out of 50 were diagnosed with subclinical pregnancy toxaemia. Specificity (detection of healthy ewes) and sensitivity (detection of ewes with subclinical pregnancy toxaemia) for TaiDoc TD-4235 and CentriVet hand-held meters were 100%, 77.8%, and 100%, 66.7%, respectively. In the receiver operating characteristic (ROC) analysis, areas under the ROC curve (AUC) were 0.976 and 0.920 for TaiDoc and CentriVet, respectively. Bland-Altman analysis revealed a bias of 0.092 mmol/L for TaiDoc and a bias of 0.132 mmol/L for CentriVet. TaiDoc hand-held meter shows a better correlation with the Randox Ranbut assay and greater sensitivity compared to the CentriVet hand-held meter. In conclusion, both TaiDoc and CentriVet hand-held meters can be securely used in the diagnosis of subclinical pregnancy toxaemia in sheep. For these reasons, subclinical pregnancy toxaemia and these devices will be evaluated within the scope of herd management programme in the sheep industry. It should also be taken into account that these conditions will affect the future fertility of the mother and offspring. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1111/rda.14589
dc.identifier.issn 0936-6768
dc.identifier.issn 1439-0531
dc.identifier.issue 5 en_US
dc.identifier.pmid 38812426
dc.identifier.scopus 2-s2.0-85194872019
dc.identifier.scopusquality Q3
dc.identifier.uri https://doi.org/10.1111/rda.14589
dc.identifier.uri https://hdl.handle.net/20.500.14720/10748
dc.identifier.volume 59 en_US
dc.identifier.wos WOS:001235021000001
dc.identifier.wosquality Q2
dc.language.iso en en_US
dc.publisher Wiley en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Centrivet en_US
dc.subject Disease en_US
dc.subject Hand-Held Meters en_US
dc.subject Ovine en_US
dc.subject Pregnancy en_US
dc.subject Taidoc en_US
dc.title Comparison of Blood Βhba Measurement Devices for Diagnosis of Subclinical Pregnancy Toxaemia in Sheep: a Field Study en_US
dc.type Article en_US

Files