YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Comparison of Efficiencies Between Shear Wave Elastography, Fine-Needle Aspiration Biopsy and American College of Radiology Thyroid Imaging Reporting and Data System Scoring System in Determining the Malignity Potential of Solid Thyroid Nodules

dc.authorid Batur, Abdussamet/0000-0003-2865-9379
dc.authorscopusid 55682194900
dc.authorscopusid 57190380888
dc.authorscopusid 11540426200
dc.authorscopusid 54998741200
dc.authorscopusid 21333559300
dc.authorscopusid 55853727900
dc.authorwosid Batur, Abdussamet/Jpk-9408-2023
dc.authorwosid Yavuz, Alpaslan/H-3947-2014
dc.contributor.author Yavuz, Alpaslan
dc.contributor.author Akbudak, Ibrahim
dc.contributor.author Ucler, Rifki
dc.contributor.author Ozgokce, Mesut
dc.contributor.author Arslan, Harun
dc.contributor.author Batur, Abdussamed
dc.date.accessioned 2025-05-10T17:20:44Z
dc.date.available 2025-05-10T17:20:44Z
dc.date.issued 2021
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Yavuz, Alpaslan] Univ Hlth Sci, Antalya Training & Res Hosp, Dept Radiol, Antalya, Turkey; [Akbudak, Ibrahim] Batman State Hosp, Dept Radiol, Batman, Turkey; [Arslan, Harun] Van Yuzuncu Yil Univ, Fac Med, Dept Radiol, Van, Turkey; [Batur, Abdussamed] Selcuk Univ, Dept Radiol, Med Fac, Konya, Turkey en_US
dc.description Batur, Abdussamet/0000-0003-2865-9379 en_US
dc.description.abstract We aimed to evaluate the efficiencies of quantitative shear-wave elastography, fine-needle aspiration (FNA) biopsy and American College of Radiology (ACR)-thyroid imaging reporting and data system (TIRADS) scoring system in determining the malignity potential of solid thyroid nodules. In period between September 2014 and January 2016, 191 solid thyroid nodules of 189 patients were enrolled in this study. The mean shear wave velocities of the nodules were recorded by acoustic radiation force impulse method. All nodules were classified according to ACR-TIRADS scoring system and underwent FNA procedure. The cytopathologic results (after FNA) were benign in nature, atypical-cytology/suspiciously malign and highly suspicious of malignity in 117, 28, and 21 nodules, respectively. The specimen from FNA was insufficient in 25 nodules. Thirty-four nodules of 33 enrolled patients were operated, and the efficiencies of shear wave elastography, FNA, and ACR-TIRADS procedures were statistically analyzed; relying on the histopathologic results, the shear-wave elastography had 83.3% sensitivity, 93.7% specificity (with a cutoff value of 2,74 m/s), the FNA had 94.4% sensitivity, 87.5% specificity, and ACR-TIRADS had 88.2% sensitivity, 94.1 specificity in determining malignant tyroid nodules (P < 0.005). Quantitative shear wave elastography is concluded to be an effective, noninvasive, and practical imaging modality with a lesser sensitivity and specificity values than TIRADS unless a lower sensitivity but a higher specificity values than FNA (93.7% vs 87.5%) in considering the malignity potential of solid thyroid nodules. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1097/RUQ.0000000000000531
dc.identifier.endpage 160 en_US
dc.identifier.issn 0894-8771
dc.identifier.issn 1536-0253
dc.identifier.issue 2 en_US
dc.identifier.pmid 32976319
dc.identifier.scopus 2-s2.0-85107390928
dc.identifier.scopusquality Q3
dc.identifier.startpage 155 en_US
dc.identifier.uri https://doi.org/10.1097/RUQ.0000000000000531
dc.identifier.uri https://hdl.handle.net/20.500.14720/10195
dc.identifier.volume 37 en_US
dc.identifier.wos WOS:000657625400013
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Lippincott Williams & Wilkins en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Thyroid Nodule en_US
dc.subject Arfi Elastography en_US
dc.subject Shear Wave Elastography en_US
dc.subject Ultrasound en_US
dc.title Comparison of Efficiencies Between Shear Wave Elastography, Fine-Needle Aspiration Biopsy and American College of Radiology Thyroid Imaging Reporting and Data System Scoring System in Determining the Malignity Potential of Solid Thyroid Nodules en_US
dc.type Article en_US

Files