YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Corneal and Lens Densitometry in Patients With Vernal Keratoconjunctivitis

dc.authorid Yilmaz, Yusuf Cem/0000-0001-5033-1041
dc.authorid Ozer, Muhammet Derda/0000-0002-3954-270X
dc.authorscopusid 57069635000
dc.authorscopusid 57203954567
dc.authorscopusid 57069698700
dc.authorwosid Ozer, Muhammet/Aaj-3679-2020
dc.contributor.author Yilmaz, Yusuf Cem
dc.contributor.author Ipek, Sefik Can
dc.contributor.author Ozer, Muhammet Derda
dc.date.accessioned 2025-05-10T17:09:48Z
dc.date.available 2025-05-10T17:09:48Z
dc.date.issued 2021
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Yilmaz, Yusuf Cem; Ipek, Sefik Can] Agri State Hosp, Ophthalmol Dept, Agri, Turkey; [Ozer, Muhammet Derda] Van Yuzuncu Yil Univ, Fac Med, Ophthalmol Dept, TR-65080 Tusba, Van, Turkey en_US
dc.description Yilmaz, Yusuf Cem/0000-0001-5033-1041; Ozer, Muhammet Derda/0000-0002-3954-270X en_US
dc.description.abstract Aim To evaluate corneal and crystalline lens densitometry in patients with vernal keratoconjunctivitis (VKC). Methods This is a case-control study. Patients with VKC and age-gender-matched healthy controls underwent a complete ophthalmologic examination with corneal and crystalline lens densitometry measurements. Additionally, the anterior chamber parameters comprise anterior and posterior K-mean and astigmatism, anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), pachymeter, and corneal volume (CV). Patients who had clinically grade 0 or grade 1 VKC and with only tarsal conjunctiva involvement during the conductance of the study were included. The variables were compared statistically. Results One hundred and nine eyes were included in the study, in which fifty-one were in the VKC group. There were 25 males in the VKC group (26 female) and 22 males in the control group (36 female). A statistically significant difference was found between the groups in terms of posterior corneal astigmatism (p = 0.02). The mean corneal pachymeter, CV, ACD, ACA, and ACV were similar in both groups (p = 0.63, p = 0.26, p = 0.60, p = 0.41, and p = 0.32, respectively). The total mean corneal densitometry in the zones extending from 6 to 10 mm and 10 to 12 mm was increased in the VKC group compared to the control group (p = 0.04 and p = 0.012, respectively). The mean crystalline lens was found to be denser in the VKC group compared to the control group (8.96 +/- 1.6 vs. 8.5 +/- 0.57, respectively, p = 0.04). Conclusion Posterior corneal astigmatism is increased in VKC cases in comparison with age- and gender-matched controls. The peripheral anterior 6-12 mm annular corneal zone showed increased corneal densitometry in VKC cases compared to the healthy subjects. Additionally, the lens clarity is found to be decreased subclinically in VKC cases compared to control cases. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1007/s10792-021-01822-0
dc.identifier.endpage 2676 en_US
dc.identifier.issn 0165-5701
dc.identifier.issn 1573-2630
dc.identifier.issue 8 en_US
dc.identifier.pmid 33754236
dc.identifier.scopus 2-s2.0-85103209504
dc.identifier.scopusquality Q2
dc.identifier.startpage 2667 en_US
dc.identifier.uri https://doi.org/10.1007/s10792-021-01822-0
dc.identifier.uri https://hdl.handle.net/20.500.14720/7230
dc.identifier.volume 41 en_US
dc.identifier.wos WOS:000631321700002
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Springer en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Vernal Keratoconjunctivitis en_US
dc.subject Corneal Densitometry en_US
dc.subject Crystalline Lens Densitometry en_US
dc.subject Anterior Chamber Depth en_US
dc.subject Anterior Chamber Volume en_US
dc.subject Anterior Chamber Angle en_US
dc.subject Pachymeter en_US
dc.subject Corneal Volume en_US
dc.title Corneal and Lens Densitometry in Patients With Vernal Keratoconjunctivitis en_US
dc.type Article en_US

Files