YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

The Effects of Low Flow and Normal Flow Desflurane Anesthesia on Liver and Renal Functions and Serum Cystatin C Levels in Geriatric Patients: a Prospective Randomized Controlled Study

dc.authorid Gunes, Haci Yusuf/0000-0003-3594-0345
dc.authorscopusid 58195300000
dc.authorscopusid 55569995300
dc.contributor.author Kol, Afife Guler
dc.contributor.author Gunes, Haci Yusuf
dc.date.accessioned 2025-05-10T17:20:15Z
dc.date.available 2025-05-10T17:20:15Z
dc.date.issued 2023
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Kol, Afife Guler; Gunes, Haci Yusuf] Van Yuzuncu Yil Univ, Fac Med, Dept Anesthesiol & Reanimat, Van, Turkiye en_US
dc.description Gunes, Haci Yusuf/0000-0003-3594-0345 en_US
dc.description.abstract Introduction: Aging is a physiological process and the elderly population is increasing. In parallel to the increasing of the elderly population, the number of geriatric patients who required an invasive procedure or surgical intervention under anesthesia are also increasing. The geriatric patients who are frailty and have a loss of functional reserve in all organ systems are more sensitive to anesthetic agents. The purpose of this research was to investigate whether low flow desflurane anesthesia also affects hepatic and kidney functions, in elderly patients. Methods: After approval from the local ethics committee, the patients were divided into two groups; as the low flow desflurane anesthesia group and the normal flow desflurane anesthesia group using the closed-envelope method. Calibration and leakage tests of the anesthesia device (Primus, Drager) were performed before anesthesia. Heamodynamics parametres, peripheral oxygen saturation, and bispectral index monitoring were performed to all patients in operating room. The blood samples were collected before anesthesia induction, after surgery, and at the postoperative 24th hour. The serum alanine aminotransferase and aspartate aminotransferase levels were measured to assess the liver damage. The serum creatinine, blood urea nitrogen, and cystatin C levels were measured to assess the kidney function. Results: The serum alanine aminotransferase, aspartate aminotransferase, blood urea nitrogen, creatinine and cystatin C levels and hemodynamic parameters, peripheral oxygen saturation and bispectral index values were similar in both groups. Conclusions: It was concluded that low-flow desflurane anesthesia does not adversely affect liver and kidney functions in geriatric patients and is as safe as normal-flow desflurane anesthesia. en_US
dc.description.woscitationindex Science Citation Index Expanded - Social Science Citation Index
dc.identifier.doi 10.29400/tjgeri.2023.332
dc.identifier.endpage 78 en_US
dc.identifier.issn 1304-2947
dc.identifier.issn 1307-9948
dc.identifier.issue 1 en_US
dc.identifier.scopus 2-s2.0-85153504713
dc.identifier.scopusquality Q4
dc.identifier.startpage 68 en_US
dc.identifier.uri https://doi.org/10.29400/tjgeri.2023.332
dc.identifier.uri https://hdl.handle.net/20.500.14720/10032
dc.identifier.volume 26 en_US
dc.identifier.wos WOS:000961949400008
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Gunes Kitabevi Ltd Sti en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Anesthesia en_US
dc.subject Cystatin C en_US
dc.subject Desflurane en_US
dc.subject Aged en_US
dc.subject Kidney en_US
dc.subject Liver en_US
dc.title The Effects of Low Flow and Normal Flow Desflurane Anesthesia on Liver and Renal Functions and Serum Cystatin C Levels in Geriatric Patients: a Prospective Randomized Controlled Study en_US
dc.type Article en_US

Files