Comparison of Ai-Assisted Cephalometric Analysis and Orthodontist-Performed Digital Tracing Analysis

dc.contributor.author Bor, Sabahattin
dc.contributor.author Cigerim, Saadet Cinarsoy
dc.contributor.author Kotan, Seda
dc.date.accessioned 2025-05-10T17:25:21Z
dc.date.available 2025-05-10T17:25:21Z
dc.date.issued 2024
dc.description Bor, Sabahattin/0000-0001-5463-0057; Kotan, Seda/0000-0003-3405-4851 en_US
dc.description.abstract Background The aim of this study was to compare and evaluate three AI-assisted cephalometric analysis platforms-CephX, WeDoCeph, and WebCeph-with the traditional digital tracing method using NemoCeph software. Material and method A total of 1500 lateral cephalometric films that met the inclusion criteria were classified as Class I, Class II, and Class III. Subsequently, 40 patients were randomly selected from each class. These selected films were uploaded to 3 AI-assisted cephalometric analysis platforms and analyzed without any manual intervention. The same films were also analyzed by an orthodontist using the NemoCeph program. Results The results revealed significant differences in key angular measurements (ANB, FMA, IMPA, and NLA) across Class I, II, and III patients when comparing the four cephalometric analysis methods (WebCeph, WeDoCeph, CephX, and NemoCeph). Notably, ANB (p < 0.05), FMA (p < 0.001), IMPA (p < 0.001), and NLA (p < 0.001) varied significantly. Linear measurements also differed, with significant differences in U1-NA (p = 0.002) and Co-A (p = 0.002) in certain classes. Repeated measurement analysis revealed variation in SNA (p = 0.011) and FMA (p = 0.030), particularly in the Class II NemoCeph group, suggesting method-dependent variability. Conclusion AI-assisted cephalometric analysis platforms such as WebCeph, WeDoCeph, and CephX give rise to notable variation in accuracy and reliability compared to traditional manual digital tracing, specifically in terms of angular and linear measurements. These results emphasize the importance of meticulous selection and assessment of analysis methods in orthodontic diagnostics and treatment planning. en_US
dc.identifier.doi 10.1186/s40510-024-00539-x
dc.identifier.issn 2196-1042
dc.identifier.scopus 2-s2.0-85206872009
dc.identifier.uri https://doi.org/10.1186/s40510-024-00539-x
dc.identifier.uri https://hdl.handle.net/20.500.14720/11341
dc.language.iso en en_US
dc.publisher Springer en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Ai-Assisted Cephalometric Analysis en_US
dc.subject Angular And Linear Measurements en_US
dc.subject 2D Lateral Films en_US
dc.subject Diagnostic Accuracy en_US
dc.title Comparison of Ai-Assisted Cephalometric Analysis and Orthodontist-Performed Digital Tracing Analysis en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id Bor, Sabahattin/0000-0001-5463-0057
gdc.author.id Kotan, Seda/0000-0003-3405-4851
gdc.author.scopusid 59373821300
gdc.author.scopusid 57216458082
gdc.author.scopusid 57219125205
gdc.coar.access open access
gdc.coar.type text::journal::journal article
gdc.description.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
gdc.description.departmenttemp [Bor, Sabahattin] Inonu Univ, Fac Dent, Dept Orthodont, Malatya, Turkiye; [Cigerim, Saadet Cinarsoy; Kotan, Seda] Van Yuzuncu Yil Univ, Fac Dent, Dept Orthodont, Van, Turkiye en_US
gdc.description.issue 1 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality N/A
gdc.description.volume 25 en_US
gdc.description.woscitationindex Science Citation Index Expanded
gdc.description.wosquality Q1
gdc.identifier.pmid 39428414
gdc.identifier.wos WOS:001337908600001
gdc.index.type WoS
gdc.index.type Scopus
gdc.index.type PubMed

Files