dc.description.abstract Background: The aim of this study was to compare the trabecular bone microstructure of the mandibular condyle in edentulous, unilateral edentulous (Kennedy Class II), and fully dentate patients. Materials and methods: The study used the cone-beam computed tomography (CBCT) images of 17 fully dentate (34 condyles), 16 edentulous (32 condyles), and 17 unilateral edentulous patients (34 condyles) aged 19 to 80 years. The trabecular bone microstructure of the mandibular condyle was evaluated on 8 consecutive cross-sectional images of these patients. In the microstructure analysis, structural model index (SMI), ellipsoid factor (EF), bone volume fraction (BV/TV), trabecular thickness (Tb.Th) and trabecular seperation (Tb.Sp) were measured. Results: There was no significant difference between the mean SMI, BV/TV, EF and Tb.Th microstructure values of each group (p = 0.243, p = 0.095, p = 0.962, p = 0.095, respectively). However, there was significant difference in terms of mean Tb.Sp between the groups (p = 0.021). The trabecular structure in all three groups was more rod-shaped. No correlation was found between age factor and microstructure values. Conclusions: Considering the in vivo microstructure analysis of CBCT images, it can be said that teeth loss does not have a significant effect on the microstructure parameters excluding Tb.Sp of mandible condyles and does not affect mandibular condyle trabecular endurance. en_US
dc.identifier.doi 10.5603/FM.a2019.0133
dc.identifier.issn 0015-5659
dc.identifier.issn 1644-3284
dc.identifier.scopus 2-s2.0-85097210509
dc.identifier.uri https://doi.org/10.5603/FM.a2019.0133
dc.identifier.uri https://hdl.handle.net/20.500.14720/13815
dc.language.iso en en_US
dc.publisher Via Medica en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Mandibular Condyle en_US
dc.subject Cone-Beam Computed Tomography en_US
dc.subject Quantitative Evaluation en_US
dc.subject Bone Tissue en_US
dc.title Evaluation of Trabecular Bone Microstructure of Mandibular Condyle in Edentulous, Unilateral Edentulous and Fully Dentate Patients Using Cone-Beam Computed Tomography en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.scopusid 57204288758
gdc.author.scopusid 57190748779
gdc.author.scopusid 57208663974
gdc.author.wosid Uğur, Mehmet/Hke-5826-2023
gdc.author.wosid Kavut, Idris/Aaf-1355-2020
gdc.coar.access open access
gdc.coar.type text::journal::journal article
gdc.description.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
gdc.description.departmenttemp [Koc, A.] Van Yuzuncu Yil Univ, Dept Oral & Maxillofacial Radiol, Fac Dent, TR-65080 Van, Turkey; [Kavut, I; Ugur, M.] Van Yuzuncu Yil Univ, Dept Prosthet Dent, Fac Dent, Van, Turkey en_US
gdc.description.endpage 834 en_US
gdc.description.issue 4 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q3
gdc.description.startpage 829 en_US
gdc.description.volume 79 en_US
gdc.description.woscitationindex Science Citation Index Expanded
gdc.description.wosquality Q3
gdc.identifier.pmid 31802471
gdc.identifier.pmid 31802471
gdc.identifier.wos WOS:000595928900020
gdc.index.type WoS
gdc.index.type Scopus
gdc.index.type PubMed

Files