Electroanalytical Determination of Salbutamol in Pharmaceutical Formulations Using Cathodically Pretreated Boron-Doped Diamond Electrode

dc.authorid Ali, Hoshyar/0000-0002-9138-485X
dc.authorid Senturk, Zuhre/0000-0002-0356-9345
dc.authorid Yardim, Yavuz/0000-0002-9587-096X
dc.authorscopusid 55807475500
dc.authorscopusid 57218701407
dc.authorscopusid 57193918077
dc.authorscopusid 55511747958
dc.authorscopusid 7004177719
dc.contributor.author Talay Pınar, P.
dc.contributor.author Ali, H.S.
dc.contributor.author Abdullah, A.A.
dc.contributor.author Yardim, Y.
dc.contributor.author Şentürk, Z.
dc.date.accessioned 2025-05-10T17:58:03Z
dc.date.available 2025-05-10T17:58:03Z
dc.date.issued 2018
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Talay Pınar] Pınar, Department of Analytical Chemistry, Van Yüzüncü Yıl Üniversitesi, Van, Turkey; [Ali] Hoshyar Saadi, Department of Analytical Chemistry, Van Yüzüncü Yıl Üniversitesi, Van, Turkey; [Abdullah] Abdullah Abdulwahed, Department of Analytical Chemistry, Van Yüzüncü Yıl Üniversitesi, Van, Turkey; [Yardim] Yavuz, Department of Analytical Chemistry, Van Yüzüncü Yıl Üniversitesi, Van, Turkey; [Şentürk] Zühre, Department of Analytical Chemistry, Van Yüzüncü Yıl Üniversitesi, Van, Turkey en_US
dc.description.abstract This paper examined for the first time the possibilities of the usage of the cathodically pretreated boron-doped diamond (CPT-BDD) electrode for the redox behavior of salbutamol (SAL) using cyclic and adsorptive stripping voltammetry. The cyclic voltammograms showed an irreversible and adsorption-controlled oxidation peak at about +1.0 V in the Britton-Robinson (BR) buffer (pH 9.0) solution. Under the optimized experimental condition, using square-wave adsorptive stripping mode, the compound yielded a well-defined voltammetric response in BR buffer, pH 9.0 at +0.95 V (vs. Ag/AgCl) (after 30 s accumulation at an open circuit condition). A linear calibration graph was obtained in the concentration range of 4.15 to 83 μg mL-1 (1.73x10-5-3.47x10-4 M). A detection limit of 1.21 μg mL-1 (5.06x10-6 M) was observed. The suggested method was also applied to the determination of SAL in the drug formulations. © 2018 Elsevier B.V., All rights reserved. en_US
dc.description.woscitationindex Emerging Sources Citation Index
dc.identifier.doi 10.12991/jrp.2018.88
dc.identifier.endpage 468 en_US
dc.identifier.issn 1309-0801
dc.identifier.issue 3 en_US
dc.identifier.scopus 2-s2.0-85056599771
dc.identifier.scopusquality N/A
dc.identifier.startpage 460 en_US
dc.identifier.trdizinid 370953
dc.identifier.uri https://doi.org/10.12991/jrp.2018.88
dc.identifier.uri https://search.trdizin.gov.tr/en/yayin/detay/370953/electroanalytical-determination-of-salbutamol-in-pharmaceutical-formulations-using-cathodicallypretreated-boron-doped-diamond-electrode
dc.identifier.volume 22 en_US
dc.identifier.wos WOS:000445922100015
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Marmara University en_US
dc.relation.ispartof Marmara Pharmaceutical Journal en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Boron-Doped Diamond Electrode en_US
dc.subject Pharmaceutical Formulations en_US
dc.subject Salbutamol en_US
dc.subject Square-Wave Adsorptive Stripping Voltammetry en_US
dc.title Electroanalytical Determination of Salbutamol in Pharmaceutical Formulations Using Cathodically Pretreated Boron-Doped Diamond Electrode en_US
dc.type Article en_US
dspace.entity.type Publication

Files