Investigation of the Effect of CT-Relative Electron Density Curves on Radiotherapy Dose Calculation

dc.contributor.author Tugrul, Taylan
dc.date.accessioned 2025-06-01T20:06:57Z
dc.date.available 2025-06-01T20:06:57Z
dc.date.issued 2025
dc.description Tuğrul, Taylan/0000-0002-0557-1334 en_US
dc.description.abstract The computerized tomography scanners play a significant role in the radiotherapy treatment planning process. The electron density obtained from the CT-RED curve can be used to determine the structure of materials, and TPS calculates the dose based on the material's composition. Errors in this curve can lead to inaccuracies in dose estimation, particularly in heterogeneous tissues. In this study, the effect of variations in the CT-RED curve on the radiation dose calculated with different algorithms was also investigated. A virtual phantom was created by the TPS system for five different environments, including two low-density (HU:-750 and HU:-300) and two high-density (HU:750 and HU:300) materials. Four different erroneous CT-RED curves were created, representing -5%, -10%, +5%, and + 10% deviations from the original CT-RED curve. The positive deviations are more prominent in regions with low HU values. On the other hand, negative errors tend to be more noticeable in regions with higher HU values. This indicates that changes in dose discrepancies are not proportional to the variations in HU. Since the HU values are converted to RED by the TPS, inconsistencies in HU values may lead to errors in the dose calculated by TPS. It is evident that errors in the CT-RED curve can affect the dose calculated by the TPS. However, it appears that this effect remains within acceptable limits. Given that different errors can combine to create significant differences, it is crucial not to overlook the importance of accurately transferring the CT-RED curve to the TPS. en_US
dc.identifier.doi 10.1097/HP.0000000000001990
dc.identifier.issn 0017-9078
dc.identifier.issn 1538-5159
dc.identifier.scopus 2-s2.0-105004596812
dc.identifier.uri https://doi.org/10.1097/HP.0000000000001990
dc.language.iso en en_US
dc.publisher Lippincott Williams & Wilkins en_US
dc.relation.ispartof Health Physics en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Computed Tomography en_US
dc.subject Dose Assessment en_US
dc.subject Electrons en_US
dc.subject Radiotherapy en_US
dc.title Investigation of the Effect of CT-Relative Electron Density Curves on Radiotherapy Dose Calculation en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id Tuğrul, Taylan/0000-0002-0557-1334
gdc.author.institutional Tugrul, Taylan
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.description.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
gdc.description.departmenttemp [Tugrul, Taylan] Van Yuzuncu Yil Univ, Med Fac, Dept Radiat Oncol, Van, Turkiye en_US
gdc.description.endpage 526 en_US
gdc.description.issue 6 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q3
gdc.description.startpage 523 en_US
gdc.description.volume 129 en_US
gdc.description.woscitationindex Science Citation Index Expanded
gdc.description.wosquality Q3
gdc.identifier.pmid 40314590
gdc.identifier.wos WOS:001610716000008
gdc.index.type WoS
gdc.index.type Scopus
gdc.index.type PubMed

Files