YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Comparison of Two Retention Appliances With Respect To Clinical Effectiveness

dc.authorid Tunca, Murat/0000-0002-9157-9390
dc.authorscopusid 57193732048
dc.authorscopusid 57210285697
dc.authorscopusid 13005120600
dc.authorwosid Kaya, Yeşim/Abh-2493-2020
dc.authorwosid Tunca, Murat/Aaz-1662-2020
dc.contributor.author Kaya, Yesim
dc.contributor.author Tunca, Murat
dc.contributor.author Keskin, Siddik
dc.date.accessioned 2025-05-10T17:33:58Z
dc.date.available 2025-05-10T17:33:58Z
dc.date.issued 2019
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Kaya, Yesim; Tunca, Murat] Yuzuncu Yil Univ, Dept Orthodont, Sch Dent, Van, Turkey; [Keskin, Siddik] Yuzuncu Yil Univ, Dept Biostat, Sch Dent, Van, Turkey en_US
dc.description Tunca, Murat/0000-0002-9157-9390 en_US
dc.description.abstract Objective: The aim of this study was to compare the clinical effectiveness of Essix and Hawley retainers during the retention period. Methods: A total of 30 subjects whose fixed orthodontic treatment results were evaluated according to the American Board of Orthodontics Phase III Objective Grading system were included in this study. After the removal of orthodontic attachments, the study participants were equally divided into two retention protocols: upper-lower Essix and upper-lower Hawley. The subjects were instructed to wear their retainers full time for 6 months, except during meals, and during nights only for 6 months. The clinical effectiveness of the retainers was evaluated according to the overjet, overbite, maxillary, and mandibular intercanine widths, intermolar widths, arch lengths, irregularity indexes, and lateral cephalometric measurements. All dental model and lateral cephalometric measurements were performed by the same investigator during three periods: pre-treatment, post-treatment, and post-retention. Results: The overjet, overbite, maxillary, and mandibular intercanine widths; intermolar widths; and arch lengths and lateral cephalometric measurements were not statistically significantly different between the groups and identified time periods. Although the maxillary and mandibular irregularity indexes increased from the post-treatment to post-retention periods, the difference was not statistically significant. Pre-treatment, post-treatment, and post-retention lateral cephalometric measurements were not statistically significantly different between and within the groups. Conclusion: According to the results of a repeated-measures analysis of variance with two factors, and although an increase was found in the maxillary and mandibular irregularity indexes, the clinical effectiveness of Essix and Hawley retainers was found to be similar during the retention period. en_US
dc.description.woscitationindex Emerging Sources Citation Index
dc.identifier.doi 10.5152/TurkJOrthod.2019.18045
dc.identifier.endpage 78 en_US
dc.identifier.issn 2528-9659
dc.identifier.issn 2148-9505
dc.identifier.issue 2 en_US
dc.identifier.pmid 31294409
dc.identifier.scopus 2-s2.0-85070224672
dc.identifier.scopusquality Q2
dc.identifier.startpage 72 en_US
dc.identifier.trdizinid 351552
dc.identifier.uri https://doi.org/10.5152/TurkJOrthod.2019.18045
dc.identifier.uri https://hdl.handle.net/20.500.14720/13660
dc.identifier.volume 32 en_US
dc.identifier.wos WOS:000472965000003
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Aves en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Orthodontic Treatment en_US
dc.subject Retention en_US
dc.subject Essix en_US
dc.subject Hawley en_US
dc.subject Relapse en_US
dc.title Comparison of Two Retention Appliances With Respect To Clinical Effectiveness en_US
dc.type Article en_US

Files