The Role of Acoustic Radiation Force Impulse Elastography in the Differentiation of Infectious and Neoplastic Liver Lesions
No Thumbnail Available
Date
2015
Journal Title
Journal ISSN
Volume Title
Publisher
Sage Publications inc
Abstract
We aimed to evaluate the effectiveness of acoustic radiation force impulse (ARFI) elastography in differentiating between hepatic lesions. The prospective study included 117 patients with liver masses. Shear wave velocity (SWV) values for lesions were determined by ARFI imaging and compared statistically. The difference between SWV values for benign and malignant hepatic masses was significant (p < 0.01). The threshold SWV value for malignant hepatic lesions was established at 2.52 m/s, and the sensitivity and specificity of this cut-off value were 97% and 66%, respectively. We concluded that ARFI elastography provides supplementary data that aid in the differential diagnosis of liver masses.
Description
Yavuz, Alpaslan/0000-0002-8796-988X
ORCID
Keywords
Acoustic Radiation Force Impulse (Arfi), Ultrasound, Focal Liver Lesions
Turkish CoHE Thesis Center URL
WoS Q
Q2
Scopus Q
Q2
Source
Volume
37
Issue
4
Start Page
312
End Page
322