The Role of Acoustic Radiation Force Impulse Elastography in the Differentiation of Infectious and Neoplastic Liver Lesions
dc.authorid | Yavuz, Alpaslan/0000-0002-8796-988X | |
dc.authorscopusid | 36993622000 | |
dc.authorscopusid | 54683893900 | |
dc.authorscopusid | 55682194900 | |
dc.authorscopusid | 55880423700 | |
dc.authorscopusid | 55547037900 | |
dc.authorscopusid | 55037389000 | |
dc.authorscopusid | 42462724900 | |
dc.authorwosid | Yavuz, Alpaslan/H-3947-2014 | |
dc.authorwosid | Göya, Cemil/Kud-6071-2024 | |
dc.authorwosid | Teke, Memik/A-5043-2016 | |
dc.authorwosid | Yavuz, Alpaslan/E-2699-2014 | |
dc.contributor.author | Goya, Cemil | |
dc.contributor.author | Hamidi, Cihad | |
dc.contributor.author | Yavuz, Alpaslan | |
dc.contributor.author | Hattapoglu, Salih | |
dc.contributor.author | Uslukaya, Omer | |
dc.contributor.author | Cetincakmak, Mehmet Guli | |
dc.contributor.author | Urakci, Zuhat | |
dc.date.accessioned | 2025-05-10T17:11:16Z | |
dc.date.available | 2025-05-10T17:11:16Z | |
dc.date.issued | 2015 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | [Goya, Cemil; Hamidi, Cihad; Hattapoglu, Salih; Cetincakmak, Mehmet Guli; Teke, Memik] Dicle Univ, Sch Med Sci, Dept Radiol, Diyarbakir, Turkey; [Yavuz, Alpaslan] Yuzuncu Yil Univ, Sch Med Sci, Dept Radiol, TR-65100 Van, Turkey; [Uslukaya, Omer] Dicle Univ, Sch Med Sci, Dept Gen Surg, Diyarbakir, Turkey; [Urakci, Zuhat] Dicle Univ, Sch Med Sci, Dept Med Oncol, Diyarbakir, Turkey | en_US |
dc.description | Yavuz, Alpaslan/0000-0002-8796-988X | en_US |
dc.description.abstract | We aimed to evaluate the effectiveness of acoustic radiation force impulse (ARFI) elastography in differentiating between hepatic lesions. The prospective study included 117 patients with liver masses. Shear wave velocity (SWV) values for lesions were determined by ARFI imaging and compared statistically. The difference between SWV values for benign and malignant hepatic masses was significant (p < 0.01). The threshold SWV value for malignant hepatic lesions was established at 2.52 m/s, and the sensitivity and specificity of this cut-off value were 97% and 66%, respectively. We concluded that ARFI elastography provides supplementary data that aid in the differential diagnosis of liver masses. | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.doi | 10.1177/0161734614566697 | |
dc.identifier.endpage | 322 | en_US |
dc.identifier.issn | 0161-7346 | |
dc.identifier.issn | 1096-0910 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.pmid | 25568051 | |
dc.identifier.scopus | 2-s2.0-84942120440 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 312 | en_US |
dc.identifier.uri | https://doi.org/10.1177/0161734614566697 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/7692 | |
dc.identifier.volume | 37 | en_US |
dc.identifier.wos | WOS:000361823100005 | |
dc.identifier.wosquality | Q2 | |
dc.language.iso | en | en_US |
dc.publisher | Sage Publications inc | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Acoustic Radiation Force Impulse (Arfi) | en_US |
dc.subject | Ultrasound | en_US |
dc.subject | Focal Liver Lesions | en_US |
dc.title | The Role of Acoustic Radiation Force Impulse Elastography in the Differentiation of Infectious and Neoplastic Liver Lesions | en_US |
dc.type | Article | en_US |